Toshiba TECRA R10 manual Safety Precautions

Models: TECRA R10

1 388
Download 388 pages 5.91 Kb
Page 231
Image 231

4.1 Overview

4 Replacement Procedures

Safety Precautions

Please read the following safety instructions before disassembling the computer and always follow the instructions while working on the computer.

DANGER: 1) Always use the genuine battery that is authorized by Toshiba or compatible with the unit. Since other battery packs have different specifications, they may be incompatible with the unit, and may burst or explode.

Never heat or disassemble the battery pack, as that could cause leakage of alkaline solution. Never throw the battery pack into a fire, as that could cause the battery pack to explode.

2)The power supply, FL inverter and other components carry high voltages. If you need to turn on the power of a partially disassembled computer to check its operation, be very careful not to touch connectors or components, in order to avoid the risk of electric shock.

Also, do not disassemble individual components in first-level maintenance.

WARNING: 1) Turn off the power and disconnect the AC adaptor from the power source, to avoid exposure to electric shock.

2)Batteries in the computer retain an electrical charge, so there is danger of electrical shock even when the computer is disconnected from an AC power source. Remove any metal jewelry or accessories such as necklaces, bracelets or rings, in order to reduce the risk of electric shock. Never work with wet or damp hands.

3)Be careful of edges and corners as these may cut.

CAUTION: 1) When you change a component, be sure the replacement component meets the required specifications. Never use foreign parts, to avoid any risk of damage to the computer.

2)To avoid any risk of short-circuit, fire or other internal damage, never allow any metal objects such as screws or paper clips to fall into the unit. Be sure to replace screws with the same size as those removed. Make sure all screws are securely fastened. Loose screws can cause short circuits, resulting in heat, smoke or fire.

3)Before lifting out an FRU or other component, make sure all cables to the component have been disconnected, in order to reduce the risk of accidental electric shock.

4)If you use AC power, be sure to use the cable that came with the computer or one recommended by Toshiba.

5)Make sure that all replacement components meet the specifications for the computer and that all cables and connectors are securely fastened, in order to avoid the risk of electric shock.

6)Some parts inside the computer, such as the CPU and cooling module, become very hot during operation. Conduct repair work after they have cooled. Be careful around the CPU and cooling module to avoid burns.

TECRA R10 Maintenance Manual (960-708)

[CONFIDENTIAL]

4-5

Page 231
Image 231
Toshiba TECRA R10 manual Safety Precautions