4 Replacement Procedure

4.28 TOUCH PAD/Fingerprint sensor board

4.28 TOUCH PAD/Fingerprint sensor board

CAUTION: Do not reuse the removed the TOUCH PAD, TP SPILL CUSHION, Fingerprint sensor board and D STICK TAPE TP.

When replacing the TP SPILL CUSHION, Fingerprint sensor board and TOUCH PAD, remove the double-sided tape left on the Fingerprint sensor board and COVER ASSY in advance.

Removing the TOUCH PAD/Fingerprint sensor board

To remove the TOUCH PAD/Fingerprint sensor board, follow the steps below and refer to Figure 4-42 to 4-45.

1.Disconnect the TP FFC from the connector on the TOUCH PAD and Fingerprint sensor board.

2.Disconnect the Fingerprint sensor board FFC from the connector on the Fingerprint sensor board.

3.Remove the following screw and TPAD PLT ASSY while releasing the latch.

• M2.5⋅4C

FLAT HEAD

⋅ 1

M2.5x4C FLAT HEAD

TP FFC

Fingerprint sensor board FFC

 

TPAD PLT ASSY

Latch

Figure 4-42 Removing the TOUCH PAD/Fingerprint sensor board (1)

4-70

[CONFIDENTIAL]

TECRA R10 Maintenance Manual (960-708)

Page 296