Power-Up Procedure

Power-Up Procedure

Introduction

 

 

This section explains how to power-up a Vanguard 7300 Series router. To power

 

 

 

down your Vanguard 7300, set the power switch to the off position.

 

 

 

 

Note

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Before you begin, be sure to review all applicable warnings and cautions in the

 

 

 

 

“Electrostatic Discharge Precautions” section on page 3-7.

Power-Up

 

 

 

 

 

 

 

 

 

 

 

 

 

Use the procedure in this table to power-up your Vanguard 7300:

Instructions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Step

 

 

 

 

Action

 

 

 

 

 

 

 

 

 

 

 

 

1

 

Check that all the cards are fully inserted and secured.

 

 

 

 

 

 

 

 

 

 

 

 

2

 

Check that all empty or open slots are covered with slot panels.

 

 

 

 

 

 

 

 

 

 

 

 

3

 

Make sure the AC power cord(s) are plugged in. For all Vanguard 7300

 

 

 

 

 

 

 

DC powered units, be sure that they are wired properly.

 

 

 

 

 

 

 

 

 

 

 

 

4

 

Flip the Vanguard 7300 AC or DC power switches to the on position. For

 

 

 

 

 

 

 

DC powered units (Version 1) depress the circuit breaker switch.

 

 

 

 

 

 

 

 

 

Note

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

If you have two power modules, set the power switches to the on position.

 

 

 

 

 

 

 

 

 

 

 

 

5

 

Check that the fan(s) operate correctly.

 

 

 

 

 

 

 

 

 

 

 

 

6

 

Check the front panel displays for the proper LED sequences.

 

Power-Up LED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

When you apply power, the fan starts and the four LEDs on the front of the CPU

Values

 

 

activate. This table lists the LED values:

 

 

 

 

 

 

LED

Meaning

Color

Indication

 

 

 

 

 

 

BFL

Board Failure

Yellow

• OFF - Normal CPU card operation

 

 

 

 

 

 

 

 

 

 

• ON - Hardware failure

 

 

 

 

 

 

 

 

 

 

• Blinks once/sec. - Waiting for cold loader

 

 

 

 

 

 

 

 

 

 

• Blinks twice/sec. - Coldloading done, waiting

 

 

 

 

 

 

 

 

 

 

for or downloading system software

 

 

 

 

 

 

CPU

CPU Activity

Green

• OFF - Indicates no CPU activity

 

 

 

 

 

 

 

 

 

 

• ON - Indicates CPU activity

 

 

 

 

 

 

PCI

PCI Activity

Green

• OFF - Indicates no PCI bus activity

 

 

 

 

 

 

 

 

 

 

• ON - Indicates PCI bus activity

 

 

 

 

 

 

CPCI

CPCI Activity

Green

• OFF - Indicates no Compact PCI bus activity

 

 

 

 

 

 

 

 

 

 

• ON - Indicates Compact PCI bus activity

 

 

 

 

 

 

 

 

 

 

Next, each pre-installed card displays power-up status on its own LEDs. During the

 

 

 