Vanguard Managed Solutions 7300 Series installation manual Port Speed

Models: 7300 Series

1 227
Download 227 pages 9.92 Kb
Page 121
Image 121

 

 

Vanguard 7300 Port Configuration

 

Port Speed

Description

 

 

 

The Port Speed value in the FRI, PPP, X.25, SDLC, and TBOP statistics screen is the

 

 

configured Port Speed for the Vanguard 7300 Serial Port, not the actual measured

 

 

port speed. The configured Port Speed field is circled in Figure 4-6.

Node: Tiger8

Address: 800

Date: 14-FEB-2001 Time:15:15:54

Detailed FRI Port Statistics: Port 301

 

 

Page: 1 of 6

Port Speed:

2048000

Operating Control Protocol: None

Protocol Role:

DTE

 

 

 

 

 

 

Port Status: Up

SP-Backup: Not Configured

Priority Station: 0

Data Summary:

 

Last Statistics Reset:

 

 

IN

OUT

 

IN

 

OUT

Characters:

430207009 57475

Characters/sec: 249460

0

Frames:

1795597

72

Frames/sec:

1041

0

Av Fr size:

239

798

Port Util.:

97%

 

0%

Frame-Relay / Physical Summary (FBOP):

 

 

 

 

 

Overrun: 0

Underrun: 0

CRC: 0

Non-Octet Aligned: 0

 

Frame Length Err: 0

Unknown DLCI Err: 0

Last Unknown DLCI: 0

Frame Length Err: 0

Unknown DLCI Err: 0

Last Unknown DLCI: 0

Interface Summary: V.35

DCE

 

INPUT

 

 

OUTPUT

 

 

 

DTR RTS MB P14

DSR DCD RI CTS

State: Connected (SIMPLE)

 

H

H

X X

H

H X H

Figure 4-6. Configured Port Speed on FRI Port Statistics Display

Set The Clock If the Clock Source parameter in the FRI, PPP, X.25, SDLC, or TBOP serial port is

Speedset to EXT or EXTLP, the Port Speed field in the FRI, PPP, X.25, SDLC, and TBOP statistics screen might not match the speed of the actual clock on the serial line.

Caution

The Clock Speed parameter in the Port Record should be configured to the Clock Speed the port is attached to. It is important to set the correct port speed, even when set to external, because statistics, throughput, and capacities use this value in their own calculations.

Note

You can determine the actual speed on the serial line by attaching an external data scope or protocol analyzer.

Operating Your Vanguard 7300

4-11

Page 121