Cabling Procedures

Serial Card

Introduction

 

All cabling for the Serial card is done at the rear of the chassis on the 8-port rear

 

panel shown in Figure 3-28.The eight ports support up to eight channels of serial

 

data for WAN networking and telecommunications applications.

Each Serial card port can be software configured for synchronous serial communication protocol. Software-configurable baud rates range from 1.2Kbps to 8Mbps. For software configuration procedures, refer to Chapter 4, Operating Your Vanguard 7300.

Figure 3-28. Serial Transition Module Connectors

Cabling the Serial Due to the high traffic density of this board, the following interface-specific cables

Card

are required with these characteristics:

 

• Serial card cables have a fixed length of seven feet

 

• Separate Data Terminal Equipment (DTE) and Data Communications

 

Equipment (DCE) cables are required because DTE/DCE operating mode is

 

determined by the physical cable characteristics

 

This table lists the cables available for use with the Serial card:

Type

DTE Cable (Plug)

DCE Cable (Socket)

Standard Serial Card Cables (English screws)

EIA232

DB25 (plug J-screw-Male)

DB25 (socket screwlock-Female)

 

 

 

EIA232

----------

DB25 (plug J-screw)

 

 

 

V35/V36

M34

M34

 

 

 

X21

DB15 (plug J-screw-Male)

DB15 (socket screwlock-Female)

 

 

 

 

Standard Serial Card Cables (Metric screws)

 

 

 

EIA232

DB25 (plug J-screw-Male)

DB25 (socket screwlock-Female)

 

 

 

EIA232

----------

DB25 (plug J-screw-Male)

 

 

 

EIA530

DB25

DB25

 

 

 

Note

For cable details, see Appendix B, Vanguard 7300 Cable Connectors and Pinouts.

Vanguard 7300 Installation

3-35

Page 109
Image 109
Vanguard Managed Solutions 7300 Series installation manual Serial Card, Type DTE Cable Plug DCE Cable Socket