Board Management

Board Management

Introduction

Board management is limited to board level actions, this includes resetting the

 

hardware, testing the hardware, downloading any necessary software to the board,

 

downloading any additional configuration information, activating and deactivating

 

the board. The board management function supports recovery of T1-E1 boards on

 

the 7300 platform.

 

The purpose of the recovery mechanism is to allow for a method of recovery of

 

faults which might occur in the T1/E1 card. This card is heavily populated by active

 

devices and supports a lot of channels. The recovery mechanism detects faults and

 

takes action to protect the node and its resource and allow other boards that are not

 

involved in the fault to continue operation.

 

Hot swap of the T1-E1 card is specifically excluded as a functional requirement in

 

this version of board recovery. The functional requirements exclude removing a

 

hardware faulty T1-E1 board and inserting a equivalent working board in its place

 

while the node is functioning and expecting the board to be activated.

 

Once recovery is triggered, the recovery function reloads the T1/E1 board and takes

 

whatever necessary steps needed to complete the process of bringing the failed card

 

on line.

 

 

The recovery preserves the topology of the operational (running) configuration.

 

Applications which use the failed resources are informed that the resource is

 

deactivated, but they are not necessarily deleted. These instances are available to

 

report the deactivate condition. Reactivation after recovery brings the system on line

 

as it was before the failure. The process does not do any booting actions such as

 

reading CMEM.

 

Configuration

 

 

Board management has configuration. In the CTP the configuration is controlled by

 

a menu entry in the Configuration Menu: Configure->Board Management. The

 

same parameters are available for viewing in the Examine and List menus. The

 

Board Management configuration is specified in the following table:

 

Keepalive Timeout

 

 

 

 

Range

1 to 20

 

 

 

 

Default

5

 

 

 

 

Description

This is the time between the sending of keepalive/heartbeat

 

 

messages. A shorter timeout allows a more responsive recovery to

 

 

occur, but with a higher processing overhead to the node. The

 

 

parameter is in tenth of seconds

 

 

 