Vanguard Managed Solutions 7300 Series Removing and Installing the Power Input Module

Models: 7300 Series

1 227
Download 227 pages 9.92 Kb
Page 178
Image 178

Replacing Power Supplies and Cooling Fans, 7310 Version 1

Removing and Installing the Power Input Module

Introduction

A Vanguard 7310 Version 1 power input module is accessible from the rear of the

 

enclosure. See Figure 6-3. Details of AC-powered modules and DC-powered

 

modules are provided in the power installation section in Chapter 3, Vanguard 7300

 

Installation.

 

 

Note

 

 

 

 

 

 

AC and DC power input modules are keyed differently. You cannot install the

 

 

wrong power unit in the wrong Vanguard 7310 enclosure.

Rear of Chassis

Mounting

Screws

 

 

 

 

ESD Bond

 

 

 

 

Point

 

Figure 6-3. Vanguard 7310 Version 1 Rear Access Power Input Module

Procedure

 

 

 

 

 

Use the steps in this table to remove the Power Input Module. To re-install the unit,

 

reverse these procedures and reconnect power to the unit:

 

 

 

 

 

 

 

Step

 

 

Action

 

 

 

 

 

 

1

Turn off power to the unit.

 

 

 

 

 

 

2

Disconnect the AC power cord or the DC connections from the unit.

 

 

 

 

 

 

3

Remove the mounting screws on the rear of the module.

 

 

 

 

 

 

4

Carefully pull on the module to slide it out of the back of the chassis.

 

 

 

 

 

Note

 

 

 

 

 

 

 

 

 

 

 

There is initial resistance until connectors disengage from the midplane.

 

 

 

 

 

 

 

6-4

Replacing Power Supplies and Cooling Fans

Page 178
Image 178
Vanguard Managed Solutions 7300 Series installation manual Removing and Installing the Power Input Module, Installation