IES-1000 User’s Guide

One AAM1008 = 1.1 kg

Wire Gauge Specifications

Chart 1 Wire Gauge Specifications

WIRE TYPE

REQUIRED AWG NO. (DIAMETER)

 

 

Telephone Wire

26 or larger

 

 

DC Power Model IES-1000 Power Wire

16 to 18

 

 

American Wire Gauge (AWG) is a measurement system for wire that specifies its thickness. As the thickness of the wire increases, the AWG number decreases.

AC Power Model Power Source

100-240VAC/1A, 50/60Hz

DC Power Model Power Source

36~72VDC /75Watt

AC Power Model Power Consumption

60 watts maximum

100-240VAC/1A, 50/60Hz

AC Power Model Fuse Rating

T3A 250VAC

DC Power Model Fuse Rating

T4A 250VDC

Operating Environment

Temperature: 0ºC — 50ºC

Humidity: 5% — 95%

Storage Environment

Temperature: -25ºC — 70ºC

Humidity: 5% — 95%

H