IES-1000 User’s Guide

Figure 6-2 Console Port Connection

6.3SHDSL Port Connections

The SHDSL ports connect to an MDF (Main Distribution Frame) and end-user equipment via telephone wires.

For detailed specifications about the associated RJ-11 connector, refer to the Pin Assignment appendix.

For more detail about MDF connections refer to the Notes About MDFs (Main Distribution Frames) section shown later.

The procedure shown next explains how to complete a single G.SHDSL connection (SAM1008) to an MDF via an SHDSL port. Instructions on ADSL connections (AAM1008) come later.

6.3.1Procedure to Complete a G.SHDSL Connection

Step 1. Connect the RJ-11 end of a telephone wire to the SHDSL port on the front panel of the SAM1008 as shown next.

Step 2. Connect the other end of the telephone wire to the upper port of an MDF (Main Distribution Frame) using a punch-down tool.

6-2

Hardware Connections