8.3The SHDSL LED(s) Do Not Turn On
The SHDSL LEDs show the operational status of SHDSL port connections. If the SHDSL LED is off, it means the link to the SHDSL modem/router is down or there is not a connection to the SHDSL port.
| Table |
STEP | CORRECTIVE ACTION |
|
|
1 | Ensure that all hardware connections are correctly installed (including the modem/router on the |
| subscriber’s side) and that all devices are turned on. |
|
|
2 | Make sure the SAM1008 SHDSL port is enabled (refer to the web configurator edit port setup |
| screens). The SHDSL ports are disabled by default. |
|
|
3 | Check the SHDSL line pin assignments shown in the Pin Assignments appendix. |
|
|
4 | Check the telephone wire connections between the G.SHDSL modem/router and the MDF(s). |
|
|
5 | Check the telephone wire and connections between the MDF(s) and ADSL port(s). |
|
|
6 | Check the telephone wire mapping on the MDF(s). |
|
|
7 | Make sure the |
|
|
8 | Make sure the line speed is consistent between the |
| Equipment) side. |
9 | If your line quality is low, you may need to select a slower line speed for both the |
| sides. Refer to the User’s Guide. |
|
|
10 | Repeat the steps above using a different SHDSL port. |
|
|
8.4The ADSL LED(s) Do Not Turn On
The ADSL LEDs show the operational status of ADSL port connections. If the ADSL LED is off, it means the link to the ADSL modem/router is down or there is not a connection to the ADSL port.
| Table |
STEP | CORRECTIVE ACTION |
|
|
1 | Ensure that all hardware connections are correctly installed (including the modem/router on the |
| subscriber’s side) and that all devices are turned on. |
2 | Make sure the AAM1008 ADSL port is enabled (refer to the User’s Guide or Quick Start Guide). The |
| ADSL ports are disabled by default. |
|
|
3 | Check the ADSL line pin assignments shown in the Pin Assignments appendix. |
|
|
4 | Check the telephone wire connections between the ADSL modem/router and the MDF(s). |
|
|
5 | Check the telephone wire and connections between the MDF(s) and ADSL port(s). |
|
|
6 | Check the telephone wire mapping on the MDF(s). |
|
|
7 | Make sure the |
|
|
8 | Make sure the upstream and downstream line rates are consistent between the |
| CPE (Customer Premise Equipment) side. |
|
|
9 | If your line quality is low, you may need to select slower upstream and downstream line rates for both |
| the |
Hardware Troubleshooting |