3Com 4500 PWR 26-PORT, 4500 PWR 50-PORT manual Rmon alarm Syntax, Undo rmon alarm entry-number

Models: 4500 26-PORT 4500 PWR 26-PORT 4500 PWR 50-PORT 4500 50-PORT

1 466
Download 466 pages 21.69 Kb
Page 405
Image 405

 

RMON Configuration Commands 399

Table 45 Output description of the display rmon statistics command

 

 

 

Field

Description

 

 

 

Interface

Port

3Com

Owner

VALID

The entry corresponding to the index is valid

octets

Received/Sent octets in sampling time

packets

Packets received/sent in sampling time

broadcast packets

Number of broadcast packets

multicast packets

Number of multicast packets

undersized packets

Number of undersized packets

oversized packets

Number of oversized packets

fragments packets

Number of undersized and CRC error packets

jabbers

Number of oversized and CRC error packets

CRC alignment errors

Number of CRC error packets

collisions

Number of collision packets

Dropped packet

Dropping packet events

(insufficient resources)

 

 

 

 

 

rmon alarm Syntax

rmon alarm entry-number alarm-variable sampling-time { delta absolute } rising-thresholdthreshold-value1 event-entry1 falling-thresholdthreshold-value2 event-entry2 [ owner text ]

undo rmon alarm entry-number

View

System view

Parameter

entry-number:Number of the entry to be added/deleted, ranging from 1 to 65535.

alarm-variable:Specifies the alarm variable with a character string, ranging from 1 to 256, in the OID dotted format, like 1.3.6.1.2.1.2.1.10.1 (or ifInOctets.1).

sampling-time:Specifies the sampling interval, ranging from 5 to 65535 (measured in seconds).

delta: Sampling type is delta.

absolute: Sampling type is absolute.

rising-thresholdthreshold-value1:Rising threshold, ranging from 0 to 2147483647.

event-entry1:Event number corresponding to the upper limit of threshold, ranging from 0 to 65535.

Page 405
Image 405
3Com 4500 PWR 26-PORT, 4500 PWR 50-PORT, 4500 50-PORT, 4500 26-PORT manual Rmon alarm Syntax, Undo rmon alarm entry-number