FA

Start Frequency

Specifies the start frequency.
Syntax
Item Description/Default
R-e
Number Any real or integer number. Default unit is Hz.
Frequency range of
the spectrum analyzer.
Equivalent
Softkey:
START FREQ .
Step Increment: Frequency span divided by 10.
Related Commands: CF, FB, FOFFSET, FS, HNLOCK, HNUNLK, MKF,
SI?
Example
OUTPUT
718;"FA
88MHZ;FB
108MHZ;"
Sets the start frequency to
88MH2,
the stop frequency
to 108
MHz
OUTPUT
718*"FA'-"
ENTER
718;l&eq
*
,
Returns the start frequency.
Stores the response from the spectrum analyzer
DISP Freq
Displays the frequency on the computer screen.
5-l 56