MKACT Activate Marker

MKACT

Activate Marker

Specifies the active marker.
Syntax
marker
Item
I
Description/Default Range
Number Any valid integer. Default value is 1.
1 to 4.
Equivalent
Softkey:
SELECT
I
2 3 4 .
Related Commands: MA, MKA, MKF.
Example
OUTPUT 7 18
;
"MKACT 4
;
‘I
Marker 4 becomes
marker
1.
Description
There can be four different markers, but only one marker can be active at any time.
When this command is used, the following results occur:
n The marker number supplied by the command is made marker 1, the active marker.
n If the marker number is not already on, the marker is turned on with preset type (position),
and the marker is placed at center screen. The trace chosen is the first displayed trace
found: trace A, trace B, trace C.
Note Using MKACT replaces marker 1 with the new marker function. The amplitude
and frequency for the previous marker are not saved.
Query Response
“MKACT?;
n
returns the marker number.
Programming Commands
5-327