Agilent Technologies Z5623A Using an External Computer to Control the Test Set, Gpib Queries

Models: Z5623A

1 138
Download 138 pages 46.21 Kb
Page 114
Image 114

Advanced Topics

Using an External Computer to Control the Test Set

Using an External Computer to Control the Test Set

Chapters 3 through 6 assume that the network analyzer is being used to control the test set. If desired, an external computer can be used instead. In order to do this, a GPIB cable needs to be connected between the computer and the network analyzer. There is no need to connect a GPIB cable between the test set and the network analyzer in this case.

The following advantages result from using an external computer:

The control can be performed by a computer program running on the computer.

GPIB queries (not available under manual control) can be sent to the test set.

GPIB Queries

When an external computer is used to control the test set, the computer can use all of the commands listed in Table 3-2and in Table 3-3. In addition, the computer can use GPIB queries that are not available when the network analyzer is used to control the test set. These are listed in Table 7-1.

Table 7-1

GPIB Queries

 

 

 

 

Query

What the test set sends in response

 

 

 

 

id?

Test Set ID

 

 

 

 

sw10?

Number of times Switch #10 has operated

 

 

 

 

sw11?

Number of times Switch #11 has operated

 

 

 

 

sw12?

Number of times Switch #12 has operated

 

 

 

 

sw13?

Number of times Switch #13 has operated

 

 

 

 

sw14?

Number of times Switch #14 has operated

 

 

 

 

sw15?

Number of times Switch #15 has operated

 

 

 

 

sw50?

Number of times Switch #50 has operated

 

 

 

 

sw51?

Number of times Switch #51 has operated

 

 

 

7 -2

Agilent Technologies Z5623A Option H48

Page 114
Image 114
Agilent Technologies Z5623A manual Using an External Computer to Control the Test Set, Gpib Queries