Measuring Multiport Devices
Models:
Z5623A
1
109
138
138
Download
138 pages
46.21 Kb
106
107
108
109
110
111
112
113
<
>
Troubleshooting
Specs
General Characteristics
Install
Warranty
Symptoms
Connector Replacement
Typical Equipment Setup
How to Send a Manual Command
Adjustments
Page 109
Image 109
6
Measuring Multiport Devices
Agilent Technologies Z5623A Option H48
6
-1
Page 108
Page 110
Page 109
Image 109
Page 108
Page 110
Contents
Manufacturing Part Number Z5623-90016 June
Agilent Technologies Z5623A Option H48
DFARS/Restricted Rights Notice
Warranty Statement
Safety Notes
Page
Contents
Calibrating the Network Analyzer
Measuring Multiport Devices
Contacting Agilent
Instrument Description
Overview
Typical Equipment Setup
Specifications
Agilent Z5623A Option H48 Guaranteed Performance Specs
Guaranteed Performance
Parameter Specification
Agilent Z5623A Option H48 Typical Performance Specs
Typical Performance
Parameter Typical Performance
Environmental Requirements
Electrical Requirements
Operating Environment
Non-Operating Storage Conditions
Weight
General Characteristics
Cabinet Dimensions
Miscellaneous Characteristics
Cleaning
Cleaning and Shipping Instructions
Shipping
Installation
Checking the Shipment
Accessories Supplied with Z5623A Option H48
Description Agilent Part Number Quantity
Recommended Equipment Not Supplied With Test Set
Recommended Additional Equipment
Description Model Or Part Number Quantity
Electrical Preparations
Familiarization with Safety Requirements
Electrical Preparations
Power Cables
Ventilation Clearance Requirements
Environmental Preparations
Example of an Antistatic Workstation
Test Set Familiarization
Front Panel Features
Front Panel
Port Connection Status LCD
Rear Panel
Rear Panel Features
Line Fuse
Gpib Address Switches
Setting the Gpib Address of the Test Set
Equation
RF Cables Connecting Network Analyzer to Test Set
Connecting and Turning on the Test Set
Length Purpose
Detailed Equipment Connection Diagram
Connecting and Turning on the Test Set
Using the Network Analyzer to
System Menu
Preparing the Analyzer to Control the Test Set
SICL/GPIB Window
Interactive Control window
PNA DeskTop
User Controller Window
Manual Control Window
Step
How to Send a Manual Command
This section explains several common errors
Common Errors in Manual Commands
Test Port Commands Connection Path
List of Gpib Commands
Command
Ooooo
Loool
Restoring the Analyzer to its Normal Configuration
Malfunctioning Command Window
Disaster Recovery
Symptoms
Recovery Procedure
Network Analyzer Screen With Four Applications Running
10 Analyzer Screen After Right-Click On My Computer Icon
12 Hardware Tab In System Properties Window
13 Device Manager Window
15 Gpib Device Disabling Message
Malfunctioning Network Analyzer
Calibrating the Network
Calibrating the Network Analyzer
Performing the Calibration
Calibration Menu on Network Analyzer
Cal Type Window When It Is First Opened
Electronic Calibration Window
10 Cal Wizard Window After Cal Is Complete
11 My Computer Window
Renaming the Calibration File
12 Root Directory of the C Drive
14 C\Program Files\Agilent Directory
16 Directory Containing Cal Files
18 Cal File Highlighted
19 Preparing to Rename the Cal File
Name of Calibration File
20 The Cal File After It Has Been Renamed
Recalling and Examining Calibrations
How to Recall a Calibration
Method 1. Calibration File Is Not On Quick Recall List
22 File Recall Window
Method 2. Calibration File Is On Quick Recall List
How to Turn a Calibration On and Off
Correction On/Off button
25 Calibration Turned On
27 Calibration Properties Button
How to Examine the Properties of a Calibration
Performance Verification
Equation 5-1 How to Set Test Limits
Setting Test Limits
Measurement Band KHz 1.3 GHz
Set
Parameter Specification Measurement Test Limit Uncertainty
Test Strategy
Return Loss
Insertion Loss
Crosstalk
Limit Test Files
Setting Up Limit Testing
Test Name File Name
Recalling the Calibration
Limit Testing for Insertion Loss
Specifying Measurement Type, Title, and Scaling
Title... Button
Title Entry Window With Insertion Loss Entered
Scale Window With Default Values
Limit Test... Button
Setting Up the Limit Table
11 Completed Limit Table for Insertion Loss
Empty Limit Table Limit Table Entries for Insertion Loss
12 Turning On Limit Testing and Limit Line Display
Turning On Limit Lines and Limit Testing
14 Save As... Button
15 Save As... Window
Checking the Limit Test File
17 Insertion Loss Test Setup, Cal File Recalled
18 Insertion Loss Test Setup, Limit Test File Recalled
19 Title Entry Window With Return Loss Port Active Entered
Limit Testing for Return Loss Port Active
Segment Beginning Ending Number Type Stimulus Response
Limit Table Entries for Return Loss Port Active
22 Return Loss Port Active Limit Test On ECal Module
Saving the Limit Test File
Setting Up Limit Testing
Recalling the Port Active Limit Test File
Limit Testing for Return Loss Port Off
Specifying the Title
Limit Table Entries for Return Loss Port Off
Recalling the Limit Test File
24 Completed Limit Table for Return Loss Port Off
Specifying Output Power
Limit Testing for Crosstalk
26 Power Window with Default Values
28 The if Bandwidth... Button
Specifying if Bandwidth and Averaging
30 if Bandwidth Window with Value Desired for Crosstalk
32 Average Window with Default Settings
34 The Status Bar Button
Setting Up Limit Testing
36 The Scale... Button
38 Completed Limit Table for Crosstalk
Limit Table Entries for Crosstalk
Turning On Limit Lines and Limit Testing
Measurements Using The Reflection Port
Verifying Return Loss and Insertion Loss Specifications
Measurements Using The Transmission Port
Pass/Fail Test Results For Insertion Loss And Return Loss
Verifying Crosstalk Specs
40 Setup for Measuring Crosstalk of Test Set
Test Ports Result
Pass/Fail Test Results for Crosstalk
Measuring Multiport Devices
Calibrating the Test System
Calibrating the Test System
Calibrating the Test System
Advanced Topics
Gpib Queries
Using an External Computer to Control the Test Set
Gpib Queries
Query What the test set sends in response
Using Rocky Mountain Basic RMB
Switch Count
Using Quick Basic or Visual Basic
Languages
HpibEolhHpib7,,0 disable EOL
Using Hpvee
Using National Instruments Visa
Control Line Commands for 9-Pin Connector
Using the Control Lines Connector
Control Lines
Suggested External Circuitry
Switch Driver Circuit For Use With Control Lines Connector
Adjustable Voltage Regulator Circuit
Using the Control Lines Connector
Service
Z5623A Option H48 Block Diagram
Adjustments
Theory of Operation
A1 Power Supply Theory
System Theory
Connector Replacement
A2 Controller and A3 Switch Driver Board Theory
A4 Front Panel Display Theory
General Troubleshooting Notes
Troubleshooting
Troubleshooting Power Supply Problems
Troubleshooting the Controller and Switch Driver Boards
Troubleshooting the Front Panel Board
Replaceable Parts for Z5623A Option H48
List of Replaceable Parts
Reference Description Part Number Quantity Designator
Replaceable Parts for Z5623A Option H48
Safety and Regulatory Information
Safety Information
Safety Information
Instrument Markings
Statement of Compliance with IEC
Regulatory Information
Declaration of Compliance with German Noise Requirements
Laermangabe Noise Declaration
Regulatory Information
Contacting Agilent
Americas
Contacting Agilent
Asia Pacific and Japan
Europe
Top
Page
Image
Contents