Advanced Topics

Using the Control Lines Connector

Figure 7-2 Switch Driver Circuit For Use With Control Lines Connector

+15 V

 

10 k

C1_in

1

 

(from Control

 

Line Connector

 

on Test Set)

16

 

9

 

8

12

13

 

 

 

 

 

3

VC

(from Power Supply)

 

 

 

 

 

2

 

C1_out

 

 

14

 

(to DUT)

 

 

 

 

 

 

15

 

10 V

 

 

 

 

 

 

11

 

 

 

 

10

 

 

 

 

6

 

 

 

 

7

 

 

5

4

Temic/Siliconix

DG413

 

-15 V

7 -8

Agilent Technologies Z5623A Option H48

Page 120
Image 120