Agilent Technologies Z5623A manual Verifying Return Loss and Insertion Loss Specifications

Models: Z5623A

1 138
Download 138 pages 46.21 Kb
Page 104
Image 104

Performance Verification

Verifying Return Loss and Insertion Loss Specifications

Verifying Return Loss and Insertion Loss

Specifications

Measurements Using The Reflection Port

Step 1. Connect an RF cable from Port 1 of the network analyzer to Test Port 1 of the test set. Connect another RF cable from Port 2 of the network analyzer to the Reflection Port of the test set. See Figure 5-39.

Figure 5-39 Setup for Measuring Insertion Loss and Return Loss of Test Set

 

 

 

 

 

 

 

E8358A

 

 

 

 

 

 

 

(300 kHz - 9.0

GHz)

GPIB

 

 

 

 

 

 

 

 

 

 

 

Port 1

 

 

 

 

Port 2

 

 

Reflection

 

 

 

 

 

Transmission

GPIB

1

2

3

4

5

6

7

8

 

Step 2. Command the test set to connect the test port to the Reflection Port. Consult Table 3-2 on page 3-9for a list of commands.

Step 3. Recall the limit test file for insertion loss. It is listed in Table 5-3 on page 5-7.

Step 4. Read the results of the insertion loss test on the screen of the network analyzer. Record the results in Table 5-8.

Step 5. Recall the limit test file for return loss (port active). It is listed in Table 5-3 on page 5-7.

Step 6. Read the results of the return loss (port active) test on the screen of the network analyzer. Record the results in Table 5-8.

5 -36