32581C

Video Processor Module - Video Processor Registers - Function 4

 

 

Table 7-7. F4BAR0+Memory Offset: Video Processor Configuration Registers (Continued)

 

 

 

 

Bit

Description

 

 

 

 

 

 

Offset 420h-423h

GenLock Register (R/W)

Reset Value: 00000000h

 

 

 

 

31:24

Reserved. Must be set to 0.

 

 

23ODD_TO (Odd Field Time Out). Indicates CGENTO0 (F4BAR0+Memory Offset 43Ch[15:0]) has expired. This bit can be reset by writing 1 to it.

22EVEN_TO (Even Field Time Out). Indicates CGENTO1 (F4BAR0+Memory Offset 43Ch[31:16]) has expired. This bit can be reset by writing 1 to it.

21:9

Reserved.

8Reserved. Set to 0.

7Reserved. Set to 0.

6Reserved. Set to 0.

5Reserved. Set to 0.

4GENLOCK_TOUT_EN (GenLock Timeout Enable).

0:Disable.

1:Enable timeout.

3VIP_VSYNC_EDGE_SEL (VIP VSYNC Edge Select). Selects which edge of the VSYNC signal should be synchronized with VIP.

0:Rising edge.

1:Falling edge.

2GX1_VSYNC_EDGE_SEL (GX1 VSYNC Edge Select). Selects which edge of the VSYNC signal should be synchronized with the GX1 module.

0:Rising edge.

1:Falling edge.

1CT_GENLOCK_EN (Enable Continuous GenLock Function).

0:The continuous GenLock function is disabled.

1:Enable locking (i.e., synchronization) of the GX1 VSYNC with the VIP VSYNC on every VSYNC (i.e., continuous lock- ing).

Note: If bit 0 (SG_GENLOCK_EN) = 1, it overrides the value of this bit.

0Reserved. Set to 0.

Offset 424h-427h

GenLock Delay Register (R/W)

Reset Value: 00000000h

 

 

 

 

31:21

Reserved.

 

 

 

 

20:0

GENLOCK_DEL (GenLock Delay). Indicates the delay (in 27 MHz clocks) between the VIP VSYNC and the GX1 module’s

 

Display Controller VSYNC.

 

 

 

 

 

 

Offset 428h-43Bh

Reserved

 

 

 

 

Offset 43Ch-43Fh

Continuous GenLock Timeout Register (R/W)

Reset Value: 1FFF1FFFh

 

 

 

31:16

CGENTO1 (Even Field Continuous GenLock Timeout).

 

 

 

 

15:0

CGENTO0 (Odd Field Continuous GenLock Timeout).

 

 

 

 

 

344

AMD Geode™ SC3200 Processor Data Book

Page 344
Image 344
AMD SC3200 manual Reserved. Set to Genlocktouten GenLock Timeout Enable, Ctgenlocken Enable Continuous GenLock Function