32581C

Electrical Specifications

9.3.15Power-Up Sequencing

Table 9-43. Power-Up Sequence Using the Power Button Timing Parameters

Symbol

Parameter

Min

Max

Unit

Comments

 

 

 

 

 

 

t1

Voltage sequence

-100

100

ms

Optimum power-up results with

 

 

 

 

 

t1 = 0.

t2

PWRBTN# inactive after VSB or VSBL

0

1

µs

PWRBTN# is an input and must

 

applied, whichever is applied last

 

 

 

be powered by VSB.

t3

PWRBTN# active pulse width

16

4000

ms

If PWRBTN# max is exceeded,

 

 

 

 

 

ONCTL# will go inactive.

 

 

 

 

 

 

t4

ONCTL# inactive after VSB applied

0

1

ms

 

t5

Signal active after PWRBTN active

14

16

ms

 

t6

VCORE and VIO applied after ONCTL#

0

 

ms

System determines when VCORE

 

active

 

 

 

and VIO are applied, hence there

 

 

 

 

 

is no maximum constraint.

 

 

 

 

 

 

t7

POR# inactive after VCORE and VIO

50

 

ms

POR# must not glitch during

 

applied

 

 

 

active time.

 

 

 

 

 

 

VSBL

 

 

t1

VSB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

t1

 

VCORE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

t6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VIO

 

 

 

 

 

t2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PWRBTN#

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

t3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ONTCL#

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

t5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PWRCNT[2:1]

 

t4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

t7

POR#

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 9-55. Power-Up Sequencing With PWRBTN# Timing Diagram

416

AMD Geode™ SC3200 Processor Data Book

Page 416
Image 416
AMD SC3200 manual PWRBTN# ONTCL# PWRCNT21 POR#