ARM ARM DUI 0224I manual Applycfgword active

Models: ARM DUI 0224I

1 402
Download 402 pages 14.06 Kb
Page 186
Image 186

Programmer’s Reference

Table 4-4 Register map for system control registers (continued)

Name

Address

Accessa

Reset

Description

level

 

 

 

 

 

 

 

 

 

SYS_OSCRESET0

0x1000008C

Read/Write

0

Value to load into the SYS_OSC0 register if the

 

 

Lockable

 

DEV CHIP RECONFIGURE pushbutton is pressed

 

 

 

 

(APPLYCFGWORD active).

 

 

 

 

At power-on reset, the SYS_OSCRESET0 is loaded

 

 

 

 

with the same default value as used for SYS_OSC0.

 

 

 

 

 

SYS_OSCRESET1

0x10000090

Read/Write

0

Value to load into the SYS_OSC1 register if the

 

 

Lockable

 

DEV CHIP RECONFIGURE pushbutton is pressed

 

 

 

 

(APPLYCFGWORD active).

 

 

 

 

At power-on reset, the SYS_OSCRESET1 is loaded

 

 

 

 

with the same default value as used for SYS_OSC1.

 

 

 

 

 

SYS_OSCRESET2

0x10000094

Read/Write

0

Value to load into the SYS_OSC2 register if the

 

 

Lockable

 

DEV CHIP RECONFIGURE pushbutton is pressed

 

 

 

 

(APPLYCFGWORD active).

 

 

 

 

At power-on reset, the SYS_OSCRESET2 is loaded

 

 

 

 

with the same default value as used for SYS_OSC2.

 

 

 

 

 

SYS_OSCRESET3

0x10000098

Read/Write

0

Value to load into the SYS_OSC3 register if the

 

 

Lockable

 

DEV CHIP RECONFIGURE pushbutton is pressed

 

 

 

 

(APPLYCFGWORD active).

 

 

 

 

At power-on reset, the SYS_OSCRESET3 is loaded

 

 

 

 

with the same default value as used for SYS_OSC3.

 

 

 

 

 

SYS_OSCRESET4

0x1000009C

Read/Write

0

Value to load into the SYS_OSC4 register if the

 

 

Lockable

 

DEV CHIP RECONFIGURE pushbutton is pressed

 

 

 

 

(APPLYCFGWORD active).

 

 

 

 

At power-on reset, the SYS_OSCRESET4 is loaded

 

 

 

 

with the same default value as used for SYS_OSC4.

 

 

 

 

 

SYS_TEST_OSC0

0x100000C0

Read only

6

32-bit counter clocked from ISC307 clock 0.

 

 

 

 

 

SYS_TEST_OSC1

0x100000C4

Read only

6

32-bit counter clocked from ISC307 clock 1.

 

 

 

 

 

SYS_TEST_OSC2

0x100000C8

Read only

6

32-bit counter clocked from ISC307 clock 2.

 

 

 

 

 

SYS_TEST_OSC3

0x100000CC

Read only

6

32-bit counter clocked from ISC307 clock 3.

 

 

 

 

 

SYS_TEST_OSC4

0x100000D0

Read only

6

32-bit counter clocked from ISC307 clock 4.

a. If Access is lockable, the register can only be written if SYS_LOCK is unlocked (see Lock Register, SYS_LOCK on page 4-24).