Table 3-11. Service Port Configuration screen fields (continued)

Using the BayStack 350 10/100 Autosense Switch

Table 3-11. Service Port Configuration screen fields (continued)

FieldDescription

Console Port Speed Allows you to set the switch service port baud rate to match the baud rate of the console terminal.

Caution: If you choose a baud rate that does not match your console terminal baud rate, you will lose communication with the configuration interface when you press [Enter]. If communication is lost, set your console terminal to match the new service port setting.

Default Value

9600

Baud

Range

2400

Baud, 4800 Baud, 9600 Baud, 19200 Baud, 38400 Baud

Console Password Enables password protection for accessing the CI through a TELNET session, a console terminal, or both.

If you set this field to Required, you can use the Logout command to restrict access to the CI. Thereafter, you will need to specify the correct password at the console-terminal prompt. Refer to the Console Read-Only Password and Console Read-Write Password field descriptions for more information.

Default Value

Not Required

Range

Not Required, Required for TELNET, Required for Console,

 

Required for Both

Console Read-OnlyWhen the Console Password field is set to Required (for TELNET, for Console, or

Passwordfor Both), this field allows read-only password access to the CI. Users can access the CI using the correct password (see Default Value below), but cannot change any parameters or use the Reset command or Reset to Default command.

Default Value

user

Range

An ASCII string of up to 15 printable characters

Console Read-WriteWhen the Console Password field is set to Required (for TELNET, for Console, or

Passwordfor Both), this field allows read-write password access to the CI. Users can log in to the CI using the correct password (see Default Value below), and can change any parameters.

Note that you can change the default passwords for read-only access and read-write access to a private password.

Caution: If you change the system-supplied default passwords, be sure to write the new passwords down and keep them in a safe place. If you forget the new passwords, you cannot access the console interface. In that case, contact Bay Networks for help.

Default Value

secure

Range

Any ASCII string of up to 15 printable characters

 

 

3-38

893-00992-B