Bay Technical Associates 350 manual Reset to Default Settings

Models: 350

1 146
Download 146 pages 41.7 Kb
Page 118
Image 118
Reset to Default Settings

Using the BayStack 350 10/100 Autosense Switch

Reset to Default Settings

The Reset to Default Settings command allows you to reset the switch and replace all configured switch parameters with the factory default settings. For a list of factory default settings, refer to Appendix C, “Switch Default Settings.”

Caution: If you choose this command, all of your configured settings will be replaced with factory default settings when you press [Enter].

The Reset to Default command takes approximately five seconds to complete. During this time, the switch initiates a self-test that comprises various diagnostic routines and subtests. The results of the self-test are displayed briefly in the BayStack 350 switch Self-Test screen (Figure 3-27), which is followed by the CI screens.

BayStack Model 350T Self-Test

 

ASIC addressing test

... Pass

ASIC buffer RAM test

... Pass

Physical layer test

... Pass

Port internal loopback test ... Pass

Self-test complete.

Figure 3-27. Self-Test screen after resetting the switch to default settings

Note: The Self-Test screen remains displayed only if the self-test detects a fatal error.

The switch LEDs also display various patterns to indicate that the subtests are in progress.

3-54

893-00992-B

Page 118
Image 118
Bay Technical Associates 350 manual Reset to Default Settings