Image 110
Table 3-15. TELNET Configuration screen fields

Using the BayStack 350 10/100 Autosense Switch

Table 3-15. TELNET Configuration screen fields

FieldDescription

TELNET Access Allows a user remote access to the CI through a TELNET session.

 

Default Value

Enabled

 

Range

Enabled, Disabled

Login Timeout

Specifies the amount of time a user has to enter the correct password at the

 

console-terminal prompt.

 

Default Value

1 minute

 

Range

0 to 10 minutes (0 indicates “no timeout”)

Login Retries

Specifies the number of times a user can enter an incorrect password at the

 

console-terminal prompt before terminating the session password prompt.

 

Default Value

3

 

Range

1 to 100

Inactivity

Specifies the amount of time the session can be inactive before it is terminated.

Timeout

Default Value

15 minutes

 

 

Range

0 to 60 minutes (0 indicates “no timeout”)

Event Logging

Specifies the types of events that will be displayed in the Event Log screen (see “Display

 

Event Log” on page 3-51).

 

Default Value

All

 

Range

All, None, Accesses, Failures

 

Description:

All: Logs the following TELNET events to the Event Log screen:

 

 

• TELNET connect: Indicates the IP address and access mode of a

 

 

TELNET session.

• TELNET disconnect: Indicates the IP address of the remote host and the access mode, due to either a logout or inactivity.

• Failed TELNET connection attempts: Indicates the IP address of the remote host whose IP address is not on the list of allowed addresses, or indicates the IP address of the remote host that did not supply the correct password.

None: Indicates that no TELNET events will be logged in the Event

Log screen.

Accesses: Logs only TELNET connect and disconnect events in the

Event Log screen.

Failures: Logs only failed TELNET connection attempts in the Event

Log screen.