Using the Console Interface

Logout

The Logout command allows a user working at a password-protected console terminal or in an active TELNET session to terminate the session.

The Logout command works as follows:

If the user is accessing the BayStack 350 switch through a TELNET session, the Logout command terminates the session.

If the user is accessing the BayStack 350 switch through a password-protected console (a terminal connected to the service port of the switch), the Logout command displays the console-terminal prompt (Figure 3-28). The user must enter the correct password to access the CI.

BayStack Model 350T HW:RevC FW:V1.00 SW:V1.00

Password: [ *************** ]

Enter Password:

Figure 3-28. Password prompt screen

You can specify whether a password is required for the TELNET session or the console terminal using the Service Port Configuration screen (see “Service Port Configuration” on page 3-37).

If the console terminal is not password protected, the system ignores the Logout command.

893-00992-B

3-55

Page 119
Image 119
Bay Technical Associates 350 manual Logout, Password prompt screen