Multiserver 5000
10. Switching Configuration
This chapter discusses switching configurations for synchronous and asynchronous data channels. Information on configuring Voice/Fax channel switching can be found in the MS1 Voice/Fax Card User’s Manual.
10.1 Switching Control
The Switching Control menu is accessed from the Command Facility Main Menu as option 5. Each option is explained in Table
COMMAND FACILITY MAIN MENU [node id]
5 SWITCHING CONTROL
SWITCHING CONTROL [node id]
1.DISABLE CHANNEL
2.ENABLE CHANNEL
3.FORCE CONNECT
4.FORCE DISCONNECT
5.FORCE CONNECT ALL
CR - ACCEPT ENTRY
M- MAIN MENU
ENTRY:
| Table |
Option | Description |
1. Disable Channel | Takes the async or voice/fax channel (or range of channels) out of service. When this |
| selection is chosen, the following prompts will appear on the screen: |
| ENTER NODE/CHANNEL# (OR RANGE OF CHANNELS)(^X TO ABORT): |
| Enter the node ID, slash, channel (port) number or range of channels. Press <cr>. The |
| Switching Control Menu will reappear on the screen. To abort, press ^X. |
| Channel ranges should be in the form: starting channel, dash, ending channel. |
| Example: To disable channels B6 through B12, enter |
| Note: Only an idle channel can be disabled. If a connected channel is |
| in the range of channels specified, the following error message |
| will appear on the screen: |
| NOT IDLE OR OOS |
| The switching software will wait until the channel disconnects |
| before taking it out of service. The only way to avoid waiting |
| and disable the connected channel is to use the forced- |
| disconnect option. |
106