Multiserver 5000

 

 

Table 11-7.

Status/Statistics (continued)

 

 

Option

Description

 

 

 

 

 

7. System Statistics

Provides two options: the period report (the report compiled during the last reporting

 

 

period) or a demand report (a snapshot of the system at the time of request).

 

 

 

 

 

 

 

 

[node id] LAST PERIOD REPORT

TIME hh:mm:ss

DATE mm/dd

 

 

 

SYSTEM STATISTICS (MUX(3) LINK A02):

 

 

 

 

 

--------------------------------------------------------------

 

 

 

 

 

TRANSMITTED

RECEIVED

 

 

 

FRAME COUNT (X100):

0

0

 

 

 

 

 

 

 

 

LOCAL/REMOTE

 

 

 

UTILIZATION %

=

COMPOSITE

20/

00

 

 

 

 

 

BUFFERS

57/

57

 

 

 

EVENT COUNTS (X1)

=

RETRANSMITS

0/

0

 

 

 

 

 

LINE ALARMS

0/

0

 

 

 

TIME (SECONDS) IN

=

SYS FLOW CTL

0/

0

 

 

 

 

 

SYNC LOSS(4)

1/

1

 

 

 

 

 

CD LOSS(4)

1/

1

 

 

 

 

 

X.21 CONNECT(5)

2/

5

 

 

 

ENTER CARRIAGE RETURN TO CONTINUE

 

 

 

 

 

 

 

 

 

 

 

(3)This would read X.21 for an X.21 link.

(4)SYNC LOSS and CD LOSS appear on Mux Link screens. They do not appear on X.21 Link screens.

(5)X.21 CONNECT appears on X.21 Link screens. It does not appear on Mux Link screens.

FRAME COUNT

The number of data frames (in

(X100)

hundreds) sent over the link since the

 

last reporting interval.

UTILIZATION %

The average percentage of

COMPOSITE

composite bandwidth used for data

 

transmission since the last reporting

 

interval.

UTILIZATION %

The highest percentage of system

BUFFERS

buffers used since the last reporting

 

interval.

EVENT

The number of frames that were

COUNTS (X1)

received in error and for which

RETRANSMITS

retransmission was requested over the

 

link since the last reporting interval.

EVENT

The number of line alarms since the

COUNTS (X1)

last reporting interval. A line alarm is

LINE ALARMS

generated whenever the error rate on

 

the link is equal to or greater than 1

 

bit retransmitted per 1000 bits.

TIME (SECONDS) The number of seconds for system-

IN SYS FLOW wide (global) buffer control on all

CONTROL channels since the last reporting interval. System-wide (global) buffer control occurs when 87 percent of the available buffer space is used.

TIME (SECONDS) Number of seconds that sync loss

IN SYNC LOSS occurred on the link since the last reporting interval.

TIME (SECONDS) Number of seconds that carrier loss

IN CD LOSS occurred on the link since the last reporting interval.

TIME (SECONDS) Usage (in seconds) of the X.21 link IN X.21 CONNECT since the last reporting interval.

150

Page 152
Image 152
Black Box 5000 manual 150