Multiserver 5000
8.5 The Interconnect Link
PORT CONFIGURATION FOR THE INTERCONNECT LINK
The Interconnect Link is for connection to another Multiserver. From the Port Configuration Menu, select option 3.
PORT CONFIGURATION [xxx]
3 INTERCONNECT LINK
SET LINK RATE [SYNC EXTERNAL CLOCKS]:
1.Sync External Clocks
2.2400 Sync Internal Clocks
3.4800 Sync Internal Clocks
4.9600 Sync Internal Clocks
5.12000 Sync Internal Clocks
6.14400 Sync Internal Clocks
7.16800 Sync Internal Clocks
8.19200 Sync Internal Clocks
9.38400 Sync Internal Clocks
10.56000 Sync Internal Clocks
11.64000 Sync Internal Clocks
CR - ACCEPT ENTRY
M- MAIN MENU
ENTRY:
For most applications, select Sync External Clocks. This is used when connecting to another Multiserver across a link via a communications device (CSU/DSU module, external CSU/DSU, or external modem).
SET LINK RATE [SYNC EXTERNAL CLOCKS]:
1 Sync External Clocks
Options 2 through 11 are used if you are connecting the Multiservers back to back in close proximity (without a communication device such as a modem or CSU/DSU) or for providing clocking to a device (such as a channel bank). These instances are relatively rare.
Important
The Multiserver must be
Once the port has been configured for an interconnect link and reset, the CCM indicator for that port will begin to flash. It will continue to flash until the link has been correctly installed and is operational.
INSTALL THE INTERCONNECT LINK
Assuming that you have installed and configured the communications device for the interconnect link (either the CSU/DSU module, an external ISU, or an external modem), connect the interconnect cable. If the external devices are not
Appendix B: Cabling Diagrams has information on the cables you should use and their pin assignments.
You can verify the integrity of the link by observing that the CCM indicator light goes off for the port being used (A1, A2, or A3).
72