Multiserver 5000
FOX
MULTISERVER
LEGEND:
INITIATING TERMINAL
LOCAL FOX
When this test is accessed, the Multiserver continually outputs a fox message to the testing terminal (Figure
DATA FLOW LOCAL FOX
DATA FLOW LOCAL SYNC AND ASYNC ECHO
FOX INTERNAL FOX MESSAGE GENERATOR
Figure 12-1. Local Channel Loopback.
test. The integrity of the components involved in the test can be judged by observing the quality of the returned data (see Figure
The terminal must be connected to a remote port for this test to operate. If there is no remote connection, the Multiserver will display NO REMOTE CONNECT ACTIVE when access to the test is attempted.
To end the test, press ^X^Y or <break>. You will be returned to the Command Mode.
REMOTE FOX
When this test begins, the local Multiserver sends the fox message through the remote unit (Multiserver or feeder mux). The message is looped back to the terminal that initiated the test. The integrity of the components involved in the test can be judged by observing the quality of the fox message (see Figure
To end the test, press ^X^Y or <break>. You will be returned to the Command Mode.
The terminal must be connected to a remote port for this test to operate. If there is no remote connection, the Multiserver will display NO REMOTE CONNECT ACTIVE when access to the test is attempted.
MODEM 1 | MODEM 1 |
| FOX |
| INITIATING |
| TERMINAL |
MULTISERVER | MULTISERVER |
| |
(OR FEEDER MUX) |
|
LEGEND: |
|
DATA FLOW REMOTE FOX |
|
DATA FLOW REMOTE ECHO |
|
FOX INTERNAL FOX MESSAGE GENERATOR |
|
1 EXTERNAL MODEM, EXTERNAL ISU, OR INTERNAL ISU MODULE | |