Multiserver 5000

Table 11-3. Command Facility Configuration (continued)

 

Option

Default

Description

8.

Output Periodic

Local

Remote Node. Periodic reports are output to a remote node. If remote

 

Report

Command

node is selected, the node ID must be named in option 9. If no remote

 

(continued)

Port

node is named in option 9, the reports will be sent to the Local Command

 

 

 

Port. The remote node will deliver the periodic reports to the output

 

 

 

location selected in its Command Facility Parameters menu. If both the

 

 

 

local and remote Multiservers are configured to send periodic reports to a

 

 

 

remote node, the local node’s messages will be lost.

 

 

 

There is a three-minute timeout on the remote node. If this report cannot

 

 

 

be sent to the device within that three minutes (link down), the periodic

 

 

 

report will be lost.

9.

Remote Node ID

None

If option 7 and/or 8 define the output report location as the remote node,

 

 

 

the remote node ID is defined here. Only one node ID can be selected if

 

 

 

both 7 and 8 request a remote node (example: 7 cannot go to Node_A

 

 

 

while 8 goes to Node_B). If both options are configured to a local output,

 

 

 

there is no need to configure a remote node ID.

 

 

 

When this option is selected, the following prompt displays:

 

 

 

ENTER REMOTE NODE-ID (^X TO ABORT):

 

 

 

Enter the node ID of the remote node. Press <cr>. Press ^X to cancel

 

 

 

and return to the Command Facility Main Menu. (You cannot use N to

 

 

 

access the next menu.)

10. External Modem

High

If the External Modem option (option 4 of the Output Event/Alarm Reports

 

Priority

 

Menu) is selected, this option defines whether alarms or events will be

 

 

 

immediately output or buffered and output when the queue is almost filled.

 

 

 

Selecting High invokes a dial sequence on all alarms and events. When

 

 

 

Low is chosen, the alarms and events will be buffered until 70% of the

 

 

 

message queue is filled. When this occurs, the dial sequence is invoked.

11. External Modem

None

If the External Modem option (option 4 of the Output Event/Alarm Reports

 

Phone #

 

Menu) is selected, this option defines the telephone number the dialout

modem will use.

When this option is selected, the following prompt displays:

ENTER EXTERNAL MODEM PHONE # (^X TO ABORT):

(continued on next page)