Multiserver 5000
Display | voice/fax signal. The indicator |
| lights on the voice/fax module show |
| the level (see Figure 13.5). When |
| this test is initiated, the display will |
| read [Active]. |
Terminate | Terminates all the tests initiated at |
Test | this menu. |
Once a test is initiated, an [Active] message is displayed on the LCD. All tests remain active until terminated with Terminate Test. The next time you cycle through the LCD Menus, an [Active] message is displayed, meaning the test was previously invoked and is still active. When a test is complete or is terminated, the LCD will display [Inactive].
For additional information on these tests, consult the MS1 Voice/Fax Card User’s Manual.
\INTEGRAL DEVICES
When this menu is selected, the screen will prompt for the channel number to be tested. If a CSU/DSU module is installed in the Multiserver, the following diagnostic options will be offerred:
Option | Description |
Local | Verifies the integrity of data entered |
Loopback | into the local ISU. |
Digital | Verifies the data path of the system |
Loopback | from a terminal at the remote unit, |
| and verifies the data path from a |
| local terminal up to the ISU module. |
| This test requires operator |
| intervention at the remote unit. The |
| Multiservers at both ends of the link |
| must be in the Remote Composite |
| Loopback Test to perform this test |
| (see above). |
Test Pattern | Generates a test pattern within the |
(TP) | ISU to verify the ability of the ISU |
| and the DDS to transfer data in both |
| directions. This requires operator |
| intervention at the remote unit. |
Local | Verifies the local ISU module by |
Loopback | using a test pattern generated |
with TP | within the ISU module. |
Terminate | Terminates all the tests initiated at |
Test | this menu. |
Once a test is initiated, an [Active] message is displayed on the LCD. All tests remain active until terminated with Terminate Test. The next time you cycle through the LCD Menus, an [Active] message is displayed, meaning the test was previously invoked and is still active. When a test is complete or is terminated, the LCD will display [Inactive].
For additional information on these tests, consult the MS1 56K CSU/DSU Module User’s Manual.
13.7 Configuration
Currently the only option in this menu that can be accessed is Hardware Overview. This function is a display only of the hardware configuration.
Press the down arrow to read the PROM # and right/left arrows to display the module information. The display shows the following items in this order:
PROM #
Slot $: NMS Module (if installed)
Slot A: Module and Revision
Slot B: Module and Revision
Slot C: Module and Revision
Slot D: Module and Revision
Slot E: Module and Revision
174