Multiserver 5000

Table 9-3. Sync Channel Characteristics (continued)

Option

Protocol

Default

Description

Number of

ASCII Bisync

1

Sets the number of leading pad characters to be

Leading Pad

EBCDIC Bisync

1

transmitted at the start of the block. This is used

Characters*

H-P Sync

1

for a time delay (1-9).

 

RTS/CTS

3

 

 

Sync-Pad

1

 

Number of

ASCII Bisync

1

Sets the number of trailing pad characters to be

Trailing Pad

EBCDIC Bisync

1

transmitted at the end of the block. External device

Characters*

H-P Sync

1

will have time to recognize the end of a block.

 

RTS/CTS

3

 

 

Sync-Pad

1

 

Buffer

DLC

NONE

Used to regulate data transmission from a device

Control

ASCII Bisync

NONE

attached to the port. The default setting (NONE)

 

EBCDIC Bisync

NONE

removes all buffer control. When this option is

 

H-P Sync

NONE

configured to CTS, the Multiserver will delay the

 

RTS/CTS

NONE

CTS signal up to 250 milliseconds for buffer control.

 

Sync-Pad

NONE

 

 

MICOM DLC

NONE

 

 

MICOM Voice

NONE

 

Encoding

DLC

NRZ

Depending upon attached device, select NRZ or

 

 

 

NRZI.

Idle Fill

DLC

FLAG FILL

There are four Idle Fill options. Selection depends

 

 

 

upon attached equipment:

 

 

 

Mark Fill sets an idle pattern of binary 1s between

 

 

 

DLC frames. Use this for IBM 3270 SDLC half-

 

 

 

duplex operation.

 

 

 

Fall Fill sets the idle pattern of hexadecimal 7E

 

 

 

(flag) between DLC frames.

 

 

 

Auto Fill and A128 Fill automatically adjust idle

 

 

 

between DLC frames to mark at the end of the

 

 

 

transmission, or flag when the transmission is not

 

 

 

finished. For IBM AS/400 5250 SDLC operation, set

 

 

 

to either Auto Fill for Modulo 8 or A128 Fill for

 

 

 

Modulo 128 frame sequencing.

Clock Flow

DLC

ENABLE

When Clock Flow Control is enabled, the local

Control

ASCII Bisync

ENABLE

Multiserver controls flow on the local port if the

 

EBCDIC Bisync

ENABLE

Channel Clocking Option has been set to

 

H-P Sync

ENABLE

RX-Internal. It does this by halting the channel’s

 

RTS/CTS

ENABLE

clock. If NONE is chosen, there is no local data flow

 

Sync-Pad

ENABLE

control. The data is discarded, and it is up to the

 

MICOM DLC

ENABLE

remote Multiserver to issue a retransmit request.

* Prompt only. No menu.

88

Page 90
Image 90