Appendix D: Messages

 

Screen Display Messages

Message

Message Type

Explanation

 

 

 

ISU LOCAL LOOPBACK

Diagnostic

The ISU on link ci has been placed in local

ACTIVE LINK # ci

 

loopback.

ISU LOCAL

Diagnostic

This test puts the local ISU on link ci in

LOOPBACK WITH TP

 

loopback, then verifies the operation of the

ACTIVE LINK # ci

 

ISU by sending and receiving the test pattern.

ISU TEST PATTERN

Diagnostic

The test-pattern generator on the ISU on link

ACTIVE LINK # ci

 

ci has been activated.

ISU TEST

Diagnostic

The test for the ISU on link ci has been

TERMINATED LINK # cl

 

terminated.

ni LAN MODULE

Info

The LAN module in ml is not available for use.

LOCATION [ml] DOWN

 

 

ni LAN MODULE

Info

The LAN module in ml is operating and

LOCATION [ml] UP

 

available.

ni LEASED LINE CONNECTION

Event

ADB has completed the leased line connection

MADE LINK ci

 

for link ci.

ni LEASE LINE OUT OF

Event

The modem is unable to communicate with the

SERVICE LINK # ci

 

remote modem over the leased lines.

ni LEASE LINE

Event

The modem is operating on the leased lines

RETRY LINK ci

 

while the dial lines are still established. ADB mode

 

 

is enabled.

ni LINE ALARM ci

Alarm

Link ci at node ni has a line alarm, indicating a high

 

 

line error rate.

LINK DOWN ci

Alarm

The local Multiserver unit has timed out (40

 

 

seconds) waiting for sync to be acquired on link ci.

 

 

Check the cabling, modem, remote Multiserver unit,

 

 

or feeder mux for errors.

LOCAL ANALOG LOOP

Diagnostic

The local analog transmit signal is being

LINK # ci

 

looped back into the local analog receiver.

LOCAL Bl-ANALOG

Diagnostic

Both the local analog and VF loopbacks are

LOOP LINK # ci

 

being run.

LOCAL Bl-DIGITAL

Diagnostic

This test includes both DTE and digital

LOOP LINK # cl

 

loopback tests.

LOCAL CHANNEL

Info

The Local Channel Configuration Menu cannot

CONFIGURATION DISABLED

 

be accessed by the async port requesting it.