Multiserver 5000
Screen Display Messages
Message | Message Type | Explanation |
|
|
|
LOCAL DIGITAL | Diagnostic | The RD signal is being internally looped to the |
LOOP LINK # ci |
| TD signal and transmitted onto the VF line. |
LOCAL DTE LOOP | Diagnostic | The TD signal is being internally looped to the |
LINK # ci |
| RD signal. |
LOCAL FOX | Diagnostic | The port is in a local fox loopback test. |
ni LOCAL LINK RESTART ci | Event | Node ni on link ci has been restarted. |
ni LOCAL SYSTEM RESET | Alarm | The local Multiserver unit has been reset. |
LOCAL TEST, ECHO INPUT | Diagnostic | The port has been placed into a local echo loopback |
|
| test. |
LOCAL TX/RX TEST | Diagnostic | The TX test pattern generator and RX error |
PATTERN LINK # ci |
| detector have both been activated. |
LOCAL VF LOOP LINK | Diagnostic | The local receiver VF signal is being routed into the |
|
| modem, looped out through the local transmitter, |
|
| and amplified through a variable gain stage. |
LOCAL 1004 HZ | Diagnostic | The local modem is transmitting a test tone |
TONE LINK # ci |
| of 1004 Hz over the telephone line. |
LOCKED PARAMETER | Event | This parameter is locked out by the hardware |
|
| configuration. |
LOGGING REPORT, | Event | Command Facility is not available because it is |
TRY LATER |
| being used to send reports. |
MODULE NOT OPERATIONAL | Info | LAN module is installed but not operational. |
<NO ANSWER> | Dialog | Indicates that no answer was received from the |
|
| async destination port. Causes include the |
|
| following: |
|
| • Remote port did not respond to connection |
|
| protocol. |
|
| • No response was received within the call |
|
| timeout period from the remote Multiserver, |
|
| although the ports are known by the local |
|
| Multiserver. |
|
| • Call inhibit is enabled (on). |
|
| • DTR = low = OOS. |
ni NO ANSWER LINK ci | Event | The calling process has discontinued due to the |
|
| absence of an answer tone on a local dial line. |