Carrier 48/50AJ specifications APPENDIX A - LOCAL DISPLAY TABLES cont, MODE — RUN STATUS cont

Models: 48/50AJ

1 190
Download 190 pages 18.39 Kb
Page 141
Image 141

APPENDIX A — LOCAL DISPLAY TABLES (cont)

MODE — RUN STATUS (cont)

ITEM

EXPANSION

RANGE

UNITS

CCN POINT

WRITE STATUS

PAGE NO.

TMGD

TIMEGUARDS

 

 

 

 

 

TG.A1

Compressor A1 Timeguard

 

 

CMPA1_TG

 

93

TG.A2

Compressor A2 Timeguard

 

 

CMPA2_TG

 

93

TG.B1

Compressor B1 Timeguard

 

 

CMPB1_TG

 

93

TG.B2

Compressor B2 Timeguard

 

 

CMPB2_TG

 

93

TG.H1

Heat Relay 1 Timeguard

 

 

HS1_TG

 

93

TG.H2

Heat Relay 2 Timeguard

 

 

HS2_TG

 

93

TG.H3

Heat Relay 3 Timeguard

 

 

HS3_TG

 

93

TG.H4

Heat Relay 4 Timeguard

 

 

HS4_TG

 

93

TG.H5

Heat Relay 5 Timeguard

 

 

HS5_TG

 

93

TG.H6

Heat Relay 6 Timeguard

 

 

HS6_TG

 

93

VERS

SOFTWARE VERSION NUMBERS

 

 

 

 

 

MBB

CESR131343-xx-xx

 

 

string

 

93

ECB1

CESR131249-xx-xx

 

 

string

 

93

ECB2

CESR131249-xx-xx

 

 

string

 

93

SCB

CESR131226-xx-xx

 

 

string

 

93

CEM

CESR131174-xx-xx

 

 

string

 

93

MARQ

CESR131171-xx-xx

 

 

string

 

93

NAVI

CESR130227-xx-xx

 

 

string

 

93

MODE — SERVICE TEST

ITEM

EXPANSION

RANGE

UNITS

CCN POINT

WRITE STATUS

PAGE NO.

TEST

Service Test Mode

ON/OFF

 

MAN_CTRL

 

 

STOP

Local Machine Disable

YES/NO

 

UNITSTOP

config

27,29,30

S.STP

Soft Stop Request

YES/NO

 

SOFTSTOP

forcible

29,30

FAN.F

Supply Fan Request

YES/NO

 

SFANFORC

forcible

29,30

F.4.CH

4 in. Filter Change Mode

YES/NO

 

FILT4CHG

 

29,30

INDP

TEST INDEPENDENT OUTPUTS

 

 

 

 

 

ECN.C

Economizer Act.Cmd.Pos.

 

 

ECONCTST

 

30

E.PWR

Economizer Power Test

 

 

ECONPTST

 

30

E.CAL

Calibrate the Economizer?

 

 

ECON_CAL

 

30

PE.A

Power Exhaust Relay A

 

 

PE_A_TST

 

30

PE.B

Power Exhaust Relay B

 

 

PE_B_TST

 

30

PE.C

Power Exhaust Relay C

 

 

PE_C_TST

 

30

H.I.R

Heat Interlock Relay

ON/OFF

 

HIR_TST

 

30

ALRM

Remote Alarm/Aux Relay

ON/OFF

 

ALRM_TST

 

30

FANS

TEST FANS

 

 

 

 

 

S.FAN

Supply Fan Relay

ON/OFF

 

SFAN_TST

 

30

S.VFD

Supply Fan VFD Speed

0-100

%

SGVFDTST

 

30

CD.F.A

Condenser Fan Circuit A

ON/OFF

 

CNDA_TST

 

30

CD.F.B

Condenser Fan Circuit B

ON/OFF

 

CNDB_TST

 

30

COOL

TEST COOLING

 

 

 

 

 

A1

Compressor A1 Relay

ON/OFF

 

CMPA1TST

 

30

A2

Compressor A2 Relay

ON/OFF

 

CMPA2TST

 

30

MLV

Min. Load Valve (HGBP)

ON/OFF

 

MLV_TST

 

30

B1

Compressor B1 Relay

ON/OFF

 

CMPB1TST

 

30

B2

Compressor B2 Relay

ON/OFF

 

CMPB2TST

 

30

HEAT

TEST HEATING

 

 

 

 

 

HT.ST

Requested Heat Stage

0-MAX

 

HTST_TST

 

30

HT.1

Heat Relay 1

ON/OFF

 

HS1_TST

 

30

HT.2

Heat Relay 2

ON/OFF

 

HS2_TST

 

30

HT.3

Relay 3 W1 Gas Valve 2

ON/OFF

 

HS3_TST

 

30

HT.4

Relay 4 W2 Gas Valve 2

ON/OFF

 

HS4_TST

 

30

HT.5

Relay 5 W1 Gas Valve 3

ON/OFF

 

HS5_TST

 

30

HT.6

Relay 6 W2 Gas Valve 3

ON/OFF

 

HS6_TST

 

30

MODE — TEMPERATURES

ITEM

EXPANSION

RANGE

UNITS

CCN POINT

WRITE STATUS

AIR.T

AIR TEMPERATURES

 

 

 

 

CTRL

CONTROL TEMPS

 

 

 

 

CTRLEDT

Evaporator Discharge Tmp

 

dF

EDT

 

CTRLLAT

Leaving Air Temperature

 

dF

LAT

 

CTRLMAT

Mixed Air Temperature

 

dF

MAT

 

CTRLR.TMP

Controlling Return Temp

 

dF

RETURN_T

forcible

CTRLS.TMP

Controlling Space Temp

 

dF

SPACE_T

forcible

SAT

Air Tmp Lvg Supply Fan

 

dF

SAT

 

OAT

Outside Air Temperature

–40 - 240

dF

OAT

forcible

RAT

Return Air Temperature

 

dF

RAT

forcible

SPT

Space Temperature

–40 - 240

dF

SPT

forcible

SPTO

Space Temperature Offset

 

^F

SPTO

forcible

S.G.LS

Staged Gas LAT Sum

 

dF

LAT_SGAS

 

S.G.L1

Staged Gas LAT 1

 

dF

LAT1SGAS

 

S.G.L2

Staged Gas LAT 2

 

dF

LAT2SGAS

 

S.G.L3

Staged Gas LAT 3

 

dF

LAT3SGAS

 

S.G.LM

Staged Gas Limit Sw.Temp

 

dF

LIMSWTMP

 

REF.T

REFRIGERANT TEMPERATURES

 

 

 

 

SCT.A

Cir A Sat.Condensing Tmp

 

dF

SCTA

 

SST.A

Cir A Sat.Suction Temp.

 

dF

SSTA

 

SCT.B

Cir B Sat.Condensing Tmp

 

dF

SCTB

 

SST.B

Cir B Sat.Suction Temp.

 

dF

SSTB

 

141

Page 141
Image 141
Carrier 48/50AJ APPENDIX A - LOCAL DISPLAY TABLES cont, MODE — RUN STATUS cont, Mode — Service Test, Mode — Temperatures