LEGEND AND NOTES FOR FIG. 15-25

LEGEND

ACircuit A

AUX

Auxiliary Contact

BCircuit B

BP

Building Pressure Transducer

CContactor, Compressor

CAP — Capacitor

CB

Circuit Breaker

CCB

Control Circuit Breaker

CCH

Crankcase Heater

CCN

Carrier Comfort Network®

CEM

Controls Expansion Module

COMP

Compressor Motor

CR

Control Relay

CS

Compressor Safety

CSB

Compressor Current Sensing Board

DP

Duct Pressure Sensor

DPT

Discharge Pressure Transducer

DS

Disconnect Switch

ECB-1

Economizer Control Board

ECB-2

Building and Supplier Air Control Board

EDT

Evaporator Discharge Air Temperature

FIOP

Factory-Installed Option

FS

Flame Sensor

FU

Fuse

GND

Ground

HC

Heat Contactor

HGBP

Hot Gas Bypass

HIR

Heat Interlock Relay

HPS

High Pressure Switch

HR

Heat Relay

HS

Hall Effect Induced Draft Motor Switch

IAQ

Indoor Air Quality

IDF

Induced Draft Fan

IDM

Induced Draft Motor

IFC

Indoor Fan Contactor

IFCB

Indoor Fan Circuit Breaker

IFM

Indoor Fan Motor

IGC

Integrated Gas Control Board

IP

Internal Compressor Protector

LAT

Staged Gas Temperature Sensor

LEN

Local Equipment Network

LS

Limit Switch

MBB

Main Base Board

MGV

Main Gas Valve

NEC

National Electrical Code

OARH

Outdoor Air Relative Humidity

OAT

Outdoor Air Temperature Sensor

OFC

Outdoor Fan Contactor

OFM

Outdoor Fan Motor

PEC

Power Exhaust Contactor

PEM

Power Exhaust Motor

NOTES:

1.Factory wiring is in accordance with the National Electrical Codes. Any field modifications or additions must be in compli- ance with all applicable codes.

2.Use 75° C min wire for field power supply, use copper wires for all units.

3.All circuit breakers “Must Trip Amps” are equal to or less than 156% RLA.

PL

Plug

RARH —

Return Air Relative Humidity

RAT

Return Air Temperature Sensor

RLA

Rated Load Amps

RLY

Relay

RS

Rollout Switch

SCB

Staged Gas Heat Control Board

SCT

Saturated Condensing Temperature Sensor

SDU

Scrolling Marquee Display

SST

Saturated Suction Temperature Sensor

T-55

Room Temperature Sensor

T-56

Room Temperature Sensor with Setpoint

TB

Terminal Block

TRAN —

Transformer

VAV

Variable Air Volume

VFD

Variable Frequency Drive

Terminal Block

Terminal (Unmarked)

Terminal (Marked)

Splice

Factory Wiring

Field Wiring

To indicate common potential only.

Not to represent wiring.

To Indicate FIOP or Accessory

THERMOSTAT MARKINGS

BM — Blower Motor

CCommon CM — Inducer Motor

CS — Centrifugal Switch

GFan

IFO — Indoor Fan On

L1 — Line 1

RThermostat Power

RT

Power Supply

SSSpeed Sensor

W1 — Thermostat Heat Stage 1

W2 — Thermostat Heat Stage 2

XAlarm Output

Y1 — Thermostat Cooling Stage 1

Y2 — Thermostat Cooling Stage 2

4.Compressor and fan motors are thermally protected — three phase motors protected against primary single phase conditions.

5.Red jumper wire must be added between R, W1, and W2 for space temperature sensor and all VAV units with heat and tem- porarily during Service Test mode when the heaters need to operate.

117