Chapter 3 Installing the Cisco uBR10012 Router
Connecting Alarm Indicators
Recommended Tools and Supplies
Table
Table | Tools and Supplies for Connecting Alarm Indicators | |
|
|
|
Quantity | Description | Comments |
|
|
|
1 | — | |
|
|
|
1 | Wire stripping tool | — |
|
|
|
6 | 14 AWG wire cables | — |
|
|
|
| If necessary | |
|
|
|
Connecting the Alarm Indicators
Use the following procedure to connect an alarm indicator to the chassis:
Step 1 Obtain sufficient wire for the desired connections. You will need two wires for each set of relays, or six separate wires to connect all three relay contacts. Use the gauge of wire required by the audible or visual alarm indicator equipment you are using (14 AWG maximum gauge).
Warning Use copper conductors only. Statement 1025
Caution The alarm contacts on the Cisco uBR10012 router are only relays and do not provide any power from the unit. These relays are rated for 60 VDC, 1 A
Step 2 Strip approximately 0.31 in. (8 mm) of insulation off the ends of the alarm indicator wire (see Figure
Figure 3-24 Stripping Insulation
8 mm max
58688
Step 3 Connect one set of alarm indicator wires to the alarm terminal block as follows (see Figure
a.Connect one lead to the common (COM) terminal.
b.If you are wiring the router in with other equipment for the alarm indicators, wire the other lead to the normally closed (NC) terminal.
c.If you are wiring the router in parallel with other equipment for the alarm indicators, wire the other lead to the normally open (NO) terminal.
| Cisco uBR10012 Universal Broadband Router Hardware Installation Guide |
|