Chapter 4 Troubleshooting the Installation

Troubleshooting the HHGE Installation

Table 4-2

Line Card Installation Troubleshooting (continued)

 

 

 

 

 

 

Symptom

 

Possible Cause

Corrective Action

 

 

 

 

 

The yellow FAIL LED blinks

1.

The SFP GBIC has been rejected

1.

Replace with a Cisco SFP GBIC.

 

 

 

because:

 

 

 

 

 

An internal fault is detected.

 

 

 

 

 

Not a Gigabit Ethernet SFP.

 

 

 

 

 

Not a Cisco SFP.

 

 

 

 

 

Two SFPs with identical

 

 

 

 

 

serial numbers are present in

 

 

 

 

 

the system.

 

 

 

 

 

There is a hardware shut down

 

 

 

 

 

 

 

The green LINK LED does not light

1.

No Ethernet connection to

1.

Make sure the upstream device has an

when you plug in the Ethernet cable

 

upstream device.

 

active Ethernet connection.

 

 

2.

The SFP GBIC was not fully

2.

Reinstall the SFP GBIC.

 

 

 

inserted or seated properly.

 

 

 

 

3.

Negotiation is not configured

3.

Reconfigure negotiation.

 

 

 

properly.

 

 

 

 

4.

Hardware shut down for that port.

4.

Enable the port.

 

 

5.

Improper SFP GBIC (FAIL LED

5.

Replace with a Cisco SFP GBIC.

 

 

 

should blink).

6.

Replace the cable.

 

 

 

 

 

 

6.

Bad cable.

 

 

 

 

 

 

 

The green LINK LED is on, but does

1.

Negotiation is off, but set to on at

1.

Set local and remote negotiation settings

not pass traffic

 

 

the remote end.

 

to the same value.

 

 

2.

Internal loopback is enabled.

2.

Disable loopback.

 

 

 

 

3.

ARP incomplete

 

 

 

 

4.

IP address not configured

 

 

 

 

 

 

 

Cisco uBR10012 Universal Broadband Router Hardware Installation Guide

4-14

OL-18259-01

Page 164
Image 164
Cisco Systems Cisco uBR10012 manual Symptom Possible Cause Corrective Action