Table 1-2. System Messages (continued)

Message

Causes

Corrective Actions

 

 

 

Plug & Play

Error encountered in

Install the NVRAM_CLR

Configuration

initializing PCIe device;

jumper in the clear position

Error

faulty system board.

(pins 1 and 3) and reboot the

 

 

system. See Figure 6-1 for

 

 

jumper location. If the

 

 

problem persists, see

 

 

"Troubleshooting Expansion

 

 

Cards."

 

 

 

Quad rank DIMM

Invalid memory

Ensure that the memory

detected after

configuration.

modules are installed in a

single rank or

 

valid configuration. See

dual rank DIMM in

 

"General Memory Module

socket.

 

Installation Guidelines."

 

 

 

Read fault

The operating system cannot

Replace the optical medium,

Requested sector

read from the hard drive,

USB medium or device.

not found

optical drive, or USB device,

Ensure that the SAS

the system could not find a

backplane, USB, or SATA

 

 

particular sector on the disk,

cables are properly

 

or the requested sector is

connected. See

 

defective.

"Troubleshooting a USB

 

 

Device," "Troubleshooting an

 

 

Optical Drive," or

 

 

"Troubleshooting a Hard

 

 

Drive" for the appropriate

 

 

drive(s) installed in your

 

 

system.

 

 

 

SATA Portx device

There is no device connected

Information only.

not found

to the specified SATA port.

 

About Your System

45

Page 45
Image 45
Dell DL2100 Plug & Play, Quad rank Dimm, Detected after, Single rank or, Dual rank Dimm, Socket, Read fault, Not found