Table
Message | Causes | Corrective Actions |
|
|
|
Unused memory | The memory configuration is | Reconfigure the memory for |
detected. DIMM’s | not optimal for mirroring or | Memory Mirroring or |
installed in the | Advanced ECC Memory | Advanced ECC Memory |
following slot | Mode. Modules in the | Mode, or change the memory |
are not available | specified slots are unused. | mode to Optimized in the |
when in mirror or |
| BIOS setup screen. See |
| "System Memory." | |
ECC modes: x,x,x |
|
|
|
|
|
Warning: A fatal | A fatal system error occurred | Check the SEL for |
error has caused | and caused the system to | information that was logged |
system reset! | reboot. | during the error. See the |
Please check the |
| applicable troubleshooting |
system event log! |
| section in "Troubleshooting |
|
| Your System" for any faulty |
|
| components specified in the |
|
| SEL. |
|
|
|
Warning: Control | The control panel is not | Install the control panel, or |
Panel is not | installed or has a faulty cable | check the cable connections |
installed. | connection. | between the display module, |
|
| the control panel board, and |
|
| the system board. See |
|
| "Control Panel Assembly." |
|
|
|
Warning! No micro | Micro code update failed. | Update the BIOS firmware. |
code update |
| See "Getting Help." |
loaded for |
|
|
processor n |
|
|
50