Table 1-2. System Messages (continued)

Message

Causes

Corrective Actions

 

 

 

Unused memory

The memory configuration is

Reconfigure the memory for

detected. DIMM’s

not optimal for mirroring or

Memory Mirroring or

installed in the

Advanced ECC Memory

Advanced ECC Memory

following slot

Mode. Modules in the

Mode, or change the memory

are not available

specified slots are unused.

mode to Optimized in the

when in mirror or

 

BIOS setup screen. See

128-bit advanced

 

"System Memory."

ECC modes: x,x,x

 

 

 

 

 

Warning: A fatal

A fatal system error occurred

Check the SEL for

error has caused

and caused the system to

information that was logged

system reset!

reboot.

during the error. See the

Please check the

 

applicable troubleshooting

system event log!

 

section in "Troubleshooting

 

 

Your System" for any faulty

 

 

components specified in the

 

 

SEL.

 

 

 

Warning: Control

The control panel is not

Install the control panel, or

Panel is not

installed or has a faulty cable

check the cable connections

installed.

connection.

between the display module,

 

 

the control panel board, and

 

 

the system board. See

 

 

"Control Panel Assembly."

 

 

 

Warning! No micro

Micro code update failed.

Update the BIOS firmware.

code update

 

See "Getting Help."

loaded for

 

 

processor n

 

 

50

About Your System

Page 50
Image 50
Dell DL2100 Unused memory, Detected. DIMM’s, Installed, Following slot, Are not available, When in mirror or, System reset