Table 1-2. System Messages (continued)

Message

Causes

Corrective Actions

 

 

 

The following

Invalid memory

Ensure that the memory

DIMMs should

configuration. The specified

modules are installed in a

match in

memory modules do not

valid configuration. See

geometry:

match in size, number of

"General Memory Module

x,x,...

ranks, or number of data

Installation Guidelines."

The following

lanes.

 

 

 

DIMMs should

 

 

match in rank

 

 

count: x,x,...

 

 

The following

 

 

DIMMs should

 

 

match in size:

 

 

x,x,...

 

 

The following

 

 

DIMMs should

 

 

match in size

 

 

and geometry:

 

 

x,x,...

 

 

The following

 

 

DIMMs should

 

 

match in size

 

 

and rank count:

 

 

x,x,...

 

 

 

 

 

Thermal sensor

A memory module without a

Replace the memory module.

not detected on x thermal sensor is installed in

See "System Memory."

 

the specified memory slot

 

 

 

 

Time-of-day

Faulty battery or faulty chip.

See "Troubleshooting the

clock stopped

 

System Battery."

 

 

 

Time-of-day not

Incorrect Time or Date

Check the Time and Date

set - please run

settings; faulty system

settings. See "Using the

SETUP program

battery.

System Setup Program and

 

 

UEFI Boot Manager." If the

problem persists, replace the system battery. See "System Memory."

About Your System

47

Page 47
Image 47
Dell DL2100 Following DIMMs should Match in size, Thermal sensor, Clock stopped, Time-of-day not, Set please run