About Your System 35
I1911 LCD Log Full.
Check SEL to
review all
Errors.
LCD overflow message. A
maximum of ten error
messages can display
sequentially on the LCD.
The eleventh message
instructs the user to check
the SEL for details on the
events.
Check the SEL for details
on the events.
Remove AC power to the
system for 10 seconds or
clear the SEL.
I1912 SEL full.
Review &
clear log.
The SEL is full of events
and is unable to log any
more.
Check the SEL for more
information and then
clear the SEL.
W1228 RAID
Controller
battery
capacity <
24hr.
Warns predictively that the
RAID battery has less than
24 hours of charge left.
Allow RAID battery to
charge to greater than 24
hours of sustained charge.
If problem persists,
replace the RAID battery.
See "Installing a RAID
Battery."
W1627 Power
required >
PSU wattage.
Check PSU and
config.
The system configuration
requires more power than
what the power supply can
provide.
Turn off power to the
system, reduce the
hardware configuration or
install higher-wattage
power supplies, and then
restart the system.
W1628 Performance
degraded.
Check PSU and
system
configur-
ation.
The system configuration
requires more power than
what the power supply can
provide, but it can boot if
throttled.
Turn off power to the
system, reduce the
hardware configuration or
install higher-wattage
power supplies, and then
restart the system.
NOTE: For the full name of an abbreviation or acronym used in this table, see "Glossary."
Table 1-1. LCD Status Messages (continued)
Code Text Cause Corrective Actions