Delta Electronics 460V Series, 230V Series manual D15, d16 Increase/Decrease Master Frequency

Models: 230V Series 460V Series 115V Series

1 187
Download 187 pages 5.92 Kb
Page 100
Image 100

Chapter 5 ParametersVFD-S Series

B.B.(N.O.)

Mx "Close": Operation available. setting by d13

B.B.(N.C.)

Mx "Open":Operation available. setting by d14

GND

NOTE

When a Base-Block signal is received, the AC drive will stop all output and the motor will free run. When base block control is deactivated, the AC drive will start its speed search function and synchronize with the motor speed, and then accelerate to Master Frequency.

External base-block signal

 

 

Pr.8-04=d1

 

 

 

 

Speed synchronization

Output

 

 

 

 

 

detection

 

 

 

 

Speed search starts with the

 

 

 

frequency

 

reference value

 

 

 

 

 

 

 

 

Output

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pr.8-06

 

 

 

 

 

 

 

 

voltage

 

 

 

 

 

 

 

 

 

 

 

 

Min. base-block time

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Speed search operation

d15, d16 Increase/Decrease Master Frequency:

Parameter values d15, d16 program the Multi-Function Input Terminals: M1 (Pr.4-04), M2 (Pr.4-05), M3 (Pr.4-06), M4 (Pr.4-07) or M5 (Pr.4-08) to incrementally increase/ decrease the Master Frequency each time an input is received.

UP

setting by d15

DOWN

setting by d16

Mx "Close": Freq. will increase by one unit.

Mx "Close":Freq. will decrease by one unit.

GND

d17, d18 PLC Function Control:

Parameter value d17 programs Multi-Function Input Terminal: M1 (Pr.4-04), M2 (Pr.4-05), M3 (Pr.4- 06), M4 (Pr.4-07) or M5 (Pr.4-08) to enable the AC drive internal PLC program. Parameter value d18 programs an input terminal to pause the PLC program.

Revision August 2006, SE08, SW V2.61

5-43

Page 100
Image 100
Delta Electronics 460V Series, 230V Series manual D15, d16 Increase/Decrease Master Frequency, D17, d18 PLC Function Control