Chapter 5 ParametersVFD-S Series

Max.

Output Pr.1-00

Freq.

60Hz

anti-slope

Factory Settings

Pr.1-00=60Hz--Max. output Freq.

Pr.4-00=60Hz--Potentiometer bias freq. Pr.4-01=1 -- bias polarity

Pr.4-02=100% -- pot. freq. gain Pr.4-03=1 -- pot. REV. motion enable

 

30

60

0

0V

Hz 10V

4mA

20mA

0Hz

 

 

 

0V

10V

4mA

20mA

Potentiometer Scale

4-04

 

Multi-function Input Terminal (M0, M1)

 

 

 

 

Settings

d0 to d29

 

Factory Setting: d1

 

 

 

 

 

 

4-05

 

Multi-function Input Terminal (M2)

 

 

 

 

 

 

 

 

Factory Setting: d6

 

 

 

 

 

 

4-06

 

Multi-function Input Terminal (M3)

 

 

 

 

 

 

 

 

Factory Setting: d7

 

 

 

 

 

 

4-07

 

Multi-function Input Terminal (M4)

 

 

 

 

 

 

 

 

Factory Setting: d8

 

 

 

 

 

 

4-08

 

Multi-function Input Terminal (M5)

 

 

 

 

 

 

 

 

Factory Setting: d9

 

 

 

 

 

Parameters & Functions table:

 

 

 

Value

 

 

Function

Value

Function

 

d0

No Function

 

d15

Up: Increment master frequency

 

d1

M0: FWD / STOP, M1: REV / STOP

d16

Down: Decrement master frequency

 

d2

M0: RUN / STOP, M1: FWD / REV

d17

Run PLC Program

 

d3

3-Wire Operation Control mode (M0,

d18

Pause PLC Program

 

M1, M2)

 

 

 

 

 

 

 

d4

External Fault (Normally Open)

d19

Counter Trigger Signal

 

 

 

 

 

 

d5

External Fault (Normally Closed)

d20

Counter Reset

 

d6

External Reset

d21

Select ACI / Deselect AVI (the priority is

 

higher than Pr. 2-00 and d26)

 

d7

Multi-Step Speed Command1

d22

PID function disable

 

d8

Multi-Step Speed Command2

d23

JOG FWD

 

d9

Multi-Step Speed Command3

d24

JOG REV

 

d10

Jog operation

 

d25

The source of master frequency is AVI. (The

 

 

priority is higher than Pr. 2-00 and d26)

 

d11

Acceleration/Deceleration Speed

d26

The source of master frequency is ACI. (The

 

Inhibit

 

priority is higher than Pr. 2-00)

 

d12

First or Second Acceleration or

d27

Press UP/DOWN key to switch

 

 

Deceleration Time Selection

 

forward/reverse (N.O.) motion

 

d13

External Base Block (N.O.)

d28

Press UP/DOWN key to switch

 

 

(Normally Open Contact Input)

 

forward/reverse (N.C.) motion

 

d14

External Base Block (N.C.)

d29

M0: 0: RUN 1: STOP, M1: no function,

 

(Normally Close Contact Input)

Direction is controlled by keypad

5-38

Revision August 2006, SE08, SW V2.61

Page 95