Pr. | Explanation | Settings | Factory | NOTE |
Setting | ||||
|
| 460V series: d4.0V to d510V | d24 |
|
Minimum Output Frequency (Fmin) | d1.0 to d60.0 Hz | d1.0 |
| |
Minimum Output Voltage (Vmin) | 230V series: d2.0V to d255V | d12.0 |
| |
| 460V series: d4.0V to d510V | d24.0 |
| |
|
|
| ||
Output Frequency Upper Limit | d1 to d110% | d100 |
| |
Output Frequency Lower Limit | d0 to d100% | d0 |
| |
Accel Time 1 | d0.1 to d600 Sec | d10.0 |
| |
Decel Time 1 | d0.1 to d600 Sec | d10.0 |
| |
Accel Time 2 | d0.1 to d600 Sec | d10.0 |
| |
Decel Time 2 | d0.1 to d600 Sec | d10.0 |
| |
Jog Acceleration / Deceleration Time | d0.1 to d600 Sec | d10.0 |
| |
Jog Frequency | d1.0 Hz to d400 Hz | d6.0 |
| |
|
| d0: Linear Accel/Decel |
|
|
|
| d1: Auto Accel, Linear Decel |
|
|
|
| d2: Linear Accel, Auto Decel |
|
|
Auto acceleration / deceleration (refer | d3: Auto Accel/Decel (Set by load) | d0 |
| |
to Accel/Decel time setting) | d4: Linear Accel; Auto Decel, Stall |
| ||
|
|
| ||
|
| Prevention during Decel |
|
|
|
| d5: Auto Accel/Decel, Stall |
|
|
|
| Prevention during Decel |
|
|
Acceleration | d0 to d7 | d0 |
| |
Deceleration | d0 to d7 | d0 |
| |
Jog Decelerating Time | d0.0 Jog Decelerating Time | d0.0 |
| |
Determined by |
| |||
|
| d0.1 to d600 |
|
|
Group 2 Operation Method Parameters |
|
|
| |
|
|
|
|
|
Pr. | Explanation | Settings | Factory | NOTE |
Setting | ||||
|
| d0: Master Frequency input |
|
|
|
| determined by digital keypad. |
|
|
|
| (record the frequency of power |
|
|
|
| loss and it can do analog |
|
|
|
| overlap plus) |
|
|
|
| d1: Master Frequency determined |
|
|
|
| by analog signal DC |
|
|
|
| (external terminal AVI). (won’t |
|
|
|
| record the frequency of power |
|
|
|
| loss and it can’t do analog |
|
|
Source of Master Frequency | overlap plus) | d0 |
| |
Command | d2: Master Frequency determined |
| ||
|
|
| ||
|
| by analog signal DC 4mA - |
|
|
|
| 20mA (external terminal AVI). |
|
|
|
| (won’t record the frequency of |
|
|
|
| power loss and it can’t do |
|
|
|
| analog overlap plus) |
|
|
|
| d3: Master Frequency determined |
|
|
|
| by Potentiometer on the digital |
|
|
|
| keypad. (won’t record the |
|
|
|
| frequency of power loss and it |
|
|
|
| can do analog overlap plus) |
|
|
Revision August 2006, SE08, SW V2.61 |