| Appendix B | ||
460V, 50/60Hz, |
|
|
|
| ||
|
|
|
|
|
|
|
kW | HP | Fundamental | Max. | Inductance (mH) |
| |
continuous |
|
|
| |||
|
| Amps | Amps | 3% impedance | 5% impedance |
|
|
|
|
| |||
0.4 | 1/2 | 2 | 3 | 20 | 32 |
|
0.75 | 1 | 4 | 6 | 9 | 12 |
|
1.5 | 2 | 4 | 6 | 6.5 | 9 |
|
2.2 | 3 | 8 | 12 | 5 | 7.5 |
|
B.3.2 AC Output Reactor Recommended Value
115V/230V, 50/60Hz,
kW | HP |
| Fundamental | Max. | Inductance (mH) | |
| continuous |
|
| |||
| Amps | 3% impedance | 5% impedance | |||
|
|
| Amps | |||
|
|
|
| |||
0.2 | 1/4 | 4 | 4 | 9 | 12 | |
|
|
|
|
|
|
|
0.4 | 1/2 | 6 | 6 | 6.5 | 9 | |
|
|
|
|
|
|
|
0.75 | 1 | 8 | 12 | 3 | 5 | |
|
|
|
|
|
|
|
1.5 | 2 | 8 | 12 | 1.5 | 3 | |
|
|
|
|
|
|
|
2.2 | 3 | 12 | 18 | 1.25 | 2.5 | |
|
|
|
|
|
|
|
460V, 50/60Hz, |
|
|
| |||
|
|
|
|
|
|
|
kW | HP |
| Fundamental | Max. | Inductance (mH) | |
| continuous |
|
| |||
| Amps | 3% impedance | 5% impedance | |||
|
|
| Amps | |||
|
|
|
| |||
0.4 | 1/2 |
| 2 | 3 | 20 | 32 |
|
|
|
|
|
|
|
0.75 | 1 |
| 4 | 6 | 9 | 12 |
|
|
|
|
|
|
|
1.5 | 2 |
| 4 | 6 | 6.5 | 9 |
|
|
|
|
|
|
|
2.2 | 3 |
| 8 | 12 | 5 | 7.5 |
|
|
|
|
|
|
|
B.3.3 Applications for AC Reactor
Connected in input circuit
Application 1 | Question |
|
|
When more than one AC motor drive is | When applying power to one of the AC motor |
connected to the same mains power, and one | drive, the charge current of the capacitors |
of them is ON during operation. | may cause voltage dip. The AC motor drive |
Revision August 2006, SE08, SW V2.61 |