Chapter 5
Group 7 Motor Parameters
Pr. | Explanation | Settings | Factory | NOTE |
Setting | ||||
Motor Rated Current | d30 to d120% | d85 |
| |
Motor | d0 to d90% | d50 |
| |
|
|
|
|
|
Torque Compensation | d0 to d10 | d1 |
| |
|
|
|
|
|
Slip Compensation | d0.0 to d10.0 | d0.0 |
| |
|
|
|
|
|
Group 8 Special Parameters |
|
|
| |
|
|
|
|
|
Pr. | Explanation | Settings | Factory | NOTE |
Setting | ||||
DC Braking Voltage Level | d0 to d30% | d0 |
| |
DC Braking Time during | d0.0 to d60.0 Sec | d0.0 |
| |
DC Braking time during Stopping | d0.0 to d60.0 Sec | d0.0 |
| |
d0.0 to d400 Hz | d0.0 |
| ||
|
| d0: Operation stops after |
|
|
|
| Momentary Power Loss |
|
|
|
| d1: Operation continues after |
|
|
| Momentary Power Loss Operation | momentary power loss, speed |
|
|
search starts with the Master | d0 |
| ||
Selection | Frequency reference value |
| ||
|
|
| ||
|
| d2: Operation continues after |
|
|
|
| momentary power loss, speed |
|
|
|
| search starts with the minimum |
|
|
|
| frequency |
|
|
Maximum Allowable Power Loss Time | d0.3 to d5.0 Sec | d2.0 |
| |
B.B. Time for Speed Search | d0.3 to d5.0 Sec | d0.5 |
| |
Current Limit for Speed Search | d30 to d200% | d150 |
| |
Skip Frequency 1 Upper Limit | d0.0 to d400 Hz | d0.0 |
| |
Skip Frequency 1 Lower Limit | d0.0 to d400 Hz | d0.0 |
| |
Skip Frequency 2 Upper Limit | d0.0 to d400 Hz | d0.0 |
| |
Skip Frequency 2 Lower Limit | d0.0 to d400 Hz | d0.0 |
| |
Skip Frequency 3 Upper Limit | d0.0 to d400 Hz | d0.0 |
| |
Skip Frequency 3 Lower Limit | d0.0 to d400 Hz | d0.0 |
| |
Auto Restart After Fault | d0 to d10 | d0 |
| |
AVR Function | d0: Enable | d2 |
| |
d1: Disable |
| |||
|
| d2: Disable when deceleration |
|
|
Software Braking Level | 115V/230V series: d350 to d450V | d380 |
| |
| 460V series: d700 to d900V | d760 |
| |
|
|
| ||
DC Braking Lower Bound Limit | d0.0 to d400 Hz | d0.0 |
|
Group 9 Communication Parameters
Revision August 2006, SE08, SW V2.61 |