Delta Electronics 230V Series, 460V Series, 115V Series manual Forward/reverse N.O. motion

Models: 230V Series 460V Series 115V Series

1 187
Download 187 pages 5.92 Kb
Page 63
Image 63

Chapter 5 ParametersVFD-S Series

Pr.

Explanation

Settings

Factory

NOTE

Setting

4-05

Multi-Function Input Terminal 2 (M2)

d10: Jog Operation

d6

 

 

d11: Accel/decel Inhibit

 

 

 

 

 

 

Multi-Function Input Terminal 3 (M3)

d12: First or Second

 

 

 

 

Acceleration/deceleration Time

d7

 

4-06

 

Selection

 

 

 

d13: External base block (N.O.)

 

 

 

 

d14: External base block (N.C.)

 

 

 

Multi-Function Input Terminal 4 (M4)

d15: Up: Increment master

 

 

 

 

frequency

 

 

4-07

 

d16: Down: Decrement master

d8

 

 

 

frequency

 

 

 

 

d17: Run PLC Program

 

 

 

 

d18: Pause PLC Program

 

 

 

 

d19: Counter Trigger Signal

 

 

 

 

d20: Counter Reset

 

 

 

 

d21: Select ACI / Deselect AVI

 

 

 

 

d22: PID Function Disabled

 

 

 

 

d23: JOG FWD

 

 

 

 

d24: JOG REV

 

 

 

 

d25: The source of master

 

 

4-08

Multi-Function Input Terminal 5(M5)

frequency is AVI.

d9

 

d26: The source of master

 

 

 

 

 

 

 

frequency is ACI.

 

 

 

 

d27: Press UP/DOWN key to switch

 

 

 

 

forward/reverse (N.O.) motion

 

 

 

 

d28: Press UP/DOWN key to switch

 

 

 

 

forward/reverse (N.C.) motion

 

 

 

 

d29: M0: 0: RUN 1: STOP, M1: no

 

 

 

 

function, Direction is controlled

 

 

 

 

by keypad

 

 

4-09

Line Start Lockout

d0: Disable

d0

 

d1: Enable

 

 

 

 

 

 

 

 

 

 

 

 

d0: Based on accel/decel time

 

 

 

 

d1: Up frequency according to

 

 

 

 

constant speed, down frequency

 

 

4-10

Up/Down Mode

according to deceleration time

d3

 

d2: Up frequency according to

 

 

 

acceleration time, down

 

 

 

 

frequenc according to constant

 

 

 

 

speed

 

 

 

 

d3: Constant speed

 

 

 

Accel/Decel Rate of Change of

 

 

 

4-11

UP/DOWN Operation with Constant

0~1000, unit: 5 Hz/sec

d1

 

 

Speed

 

 

 

 

 

 

 

 

Group 5 Multi-Step Speed and PLC Parameters

 

 

 

 

 

 

 

Pr.

Explanation

Settings

Factory

NOTE

 

 

 

Setting

 

5-00

1st Step Speed Freq.

d0.0 to d400 Hz

d0.0

 

5-01

2nd Step Speed Freq.

d0.0 to d400 Hz

d0.0

 

5-6

Revision August 2006, SE08, SW V2.61

Page 63