Chapter 5 ParametersVFD-S Series

0-08

0-07

Displays 0 when

 

 

 

 

 

Correct Password

entering correct

password into

 

END

Pr.0-07.

 

 

 

 

 

 

 

 

 

 

 

 

 

0-

 

08

 

 

Displays

 

0 when

 

 

 

entering correct

 

password into

 

Pr.0-07.

Incorrect Password

END

0-07

3 chances to enter the correct password.

1st time displays "d 1" if password is incorrect. 2nd time displays "d 2", if password is incorrect. 3rd time displays " codE" (blinking)

If the password was entered incorrectly after three tries, the keypad will be locked.

Turn the power OFF/ON to re-enter the password.

0-09

Memory Mode Selections

Unit: 1

 

 

 

 

 

Settings

d0 to d63

Factory Setting: d8

 

 

 

 

This parameter is determined to save frequency, operation direction and parameter setting

after power off or not.

Setting method: input to this parameter after converting binary 6-bit to decimal. Refer to

following two tables for detail.

Bit 0

Reserved

Bit 1

0: save frequency

1: not save frequency

 

Bit 2

Reserved

Bit 3

0: save direction

1: not save direction

 

Bit 4

0: save parameters (except Pr.0-09 and Pr.0-02)

1: not save parameters

 

Bit 5

0: save Pr.0-09

1: not save Pr. 0-09

 

5-20

Revision August 2006, SE08, SW V2.61

Page 77