FISCO Power Supply

Reference Manual

Rosemount 2410

300530EN, Rev BA September 2012

FISCO Power Supply

Ex de[ib] IIB T4 (-50 °C Ta +70 °C) Uo=15V, lo=354mA, Po=5.32W Um=250 V

HART/4-20 mA ENTITY IS I/O Option

Active Current Loop

Ex de[ia IIC] IIB T4 (-50 °C<Ta<+70 °C) Uo = 23.1 V, Io = 95.3 mA, Po = 550 mW Group IIC: Co 0.14 uF, Lo 3.9 mH Group IIB: Co 1.0 uF, Lo 15 mH Group IIA: Co 3.67 uF, Lo 33 mH

Passive Current Loop

Ex de[ib IIC] IIB T4 (-50 °C<Ta<+70 °C)

Ui = 30.0 V, Ii = 300 mA, Ci = 0 μF, Li = 0 mH

B-8

Appendix B. Product Certifications

Page 116
Image 116
Emerson Process Management Rosemount 2410 manual FISCO Power Supply, Reference Manual, HART/4-20 mA ENTITY IS I/O Option