C.8 ARITHMETIC OPERATIONS

Reference Manual

300530EN, Rev BA September 2012

Rosemount 2410

C.8 ARITHMETIC OPERATIONS

Figure C-12. Rosemount 2410 Holding registers for arithmetic operations

The Rosemount 2410 Tank Hub supports various arithmetic calculations. Holding Registers 4800 to 4879 are used for up to 10 arithmetic operations. You may perform several operations for one or many tanks.

Arithmetic operations can, for example, be used to calculate the difference between product levels measured by two different level gauges.

Name

Holding Register no.

Description

 

 

 

Arithmetic1 operation

4800

Arithmetic operation to perform

 

 

0: None

 

 

1: Subtraction

 

 

2: Addition

 

 

3: Multiplication

 

 

4: Division

 

 

 

Arithmetic1 miscellaneous

4801

Ignore Source Unit

configuration

 

 

Arithmetic1 TMV type

4802

Tank measurement variable in which the result is stored.

destination

 

56: TMV Delta Level

 

 

60: TMV User Defined 1

 

 

61: TMV User Defined 2

 

 

62: TMV User Defined 3

 

 

63: TMV User Defined 4

 

 

64: TMV User Defined 5

 

 

 

Arithmetic1 tank number

4803

Tank in which the result is stored.

destination

 

0: Not active

 

 

1: Tank 1

 

 

2: Tank 2

 

 

3: Tank 3

 

 

4: Tank 4

 

 

5: Tank 5

 

 

6: Tank 6

 

 

7: Tank 7

 

 

8: Tank 8

 

 

9: Tank 9

 

 

10: Tank 10

Arithmetic1 A TMV Type

4804

Tank measurement variable type for the arithmetic

 

 

operation parameter A

 

 

 

Arithmetic1 A tank number

4805

Tank for the arithmetic operation parameter A.

 

 

0: Not active

 

 

1: Tank 1

 

 

2: Tank 2

 

 

3: Tank 3

 

 

4: Tank 4

 

 

5: Tank 5

 

 

6: Tank 6

 

 

7: Tank 7

 

 

8: Tank 8

 

 

9: Tank 9

 

 

10: Tank 10

Arithmetic1 B TMV Type

4806

Tank measurement variable type for the arithmetic

 

 

operation parameter B